Literature DB >> 6118405

A comparative study on the performance of asbestos-free depth-filters for removal of pyrogens from infusion fluids.

C Baggerman, C Brandsema, M Humer, J Visser.   

Abstract

Three asbestos-free depth-filters were compared with traditionally used asbestos-containing depth-filters for chemical integrity, physical integrity and pyrogen retention. With chemical and physical integrity only minor differences between the various filter types were seen. One asbestos-free depth-filter, based on charcoal, showed poor pyrogen-retention; this might be due to a high flow rate used. Asbestos-free depth-filters based on kieselguhr or on a mixture of kaolin and alumina proved to be good alternatives; these filters have proved to be suitable for the removal of pyrogens from electrolyte- or carbohydrate-containing infusion fluids.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 6118405     DOI: 10.1111/j.2042-7158.1981.tb13905.x

Source DB:  PubMed          Journal:  J Pharm Pharmacol        ISSN: 0022-3573            Impact factor:   3.765


  1 in total

1.  Microbiological contamination of raw materials for large-volume parenterals.

Authors:  C Baggerman; L M Kannegieter
Journal:  Appl Environ Microbiol       Date:  1984-09       Impact factor: 4.792