Literature DB >> 6106227

In vivo n.m.r. imaging in medicine: the Aberdeen approach, both physical and biological.

J Mallard, J M Hutchison, W A Edelstein, C R Ling, M A Foster, G Johnson.   

Abstract

A novel magnetic field and radio frequency (1.7 MHz) pulse sequence is described for a whole body n.m.r. imaging machine under construction. Selective excitation is used to obtain signals from successive lines of proton spins(water) across the body to build up an image of a transverse section. The images display spin concentration and spin-lattice relaxation time, T1, separately. For a 50% change in T1 to be discerned in the human trunk, a spatial resolution of 2 cm3 is expected for a 2 min scan and 0.5 cm3 for a 30 min scan. Very preliminary images at the present incomplete stage of development show the geometrical accuracy and T1 discrimination: an in vivo image demonstrates some of the difficulties to be overcome. In vitro measurements of normal rabbit tissue samples have been made at 24 MHz to map the T1 distributions that can be expected from normal subjects. The transposition of this information from rabbit to man, and from 24 MHz to 2.5 MHz have been checked and the comparison shown to be meaningful. Of pathological samples, human breast tumour and human liver metastases offer a good contrast to their surrounding tissue, and an experimental investigation has shown that tissue immediately surrounding a tumour also has an elevated T1 value. A wide range of abnormalities that are associated with abnormal fluid formation in the body may be amenable to imaging by the n.m.r. technique. Potential hazards are believed to be small in the present generation of equipment.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 6106227     DOI: 10.1098/rstb.1980.0071

Source DB:  PubMed          Journal:  Philos Trans R Soc Lond B Biol Sci        ISSN: 0962-8436            Impact factor:   6.237


  3 in total

Review 1.  A history of the treatment of craniopharyngiomas.

Authors:  Arthur J DiPatri; Vikram Prabhu
Journal:  Childs Nerv Syst       Date:  2005-07-26       Impact factor: 1.475

2.  Nuclear magnetic resonance (NMR) tomographic imaging for popliteal cysts in rheumatoid arthritis.

Authors:  R G Hull; J A Rennie; C J Eastmond; J M Hutchison; F W Smith
Journal:  Ann Rheum Dis       Date:  1984-02       Impact factor: 19.103

3.  Non-invasive monitoring of tissue response to radiotherapy by localised proton spin-lattice relaxation time in mice.

Authors:  K Tanaka; Y Kikuchi; Y Yamada
Journal:  Med Biol Eng Comput       Date:  1995-01       Impact factor: 2.602

  3 in total