End-diastolic and end-systolic ventricular volume clamper for isolated canine heart.

H Suga, K Sagawa.   

Abstract

We devised a servo-controlled pump system which can clamp both end-diastolic and end-systolic volumes of the left ventricle of an excised, supported canine heart at desirable values in the face of changing patterns of ejection and filling. The system consists of a Bellofram cylinder and a powerful electromagnetic shaker which is driven by a position servo circuit. A water-filled balloon placed in the ventricle was connected to the water housing of the cylinder. As the ECG triggered the system, a fixed amount of water reciprocated between the heart and the cylinder in a programmed manner. The onset, duration, and speed of ejection and those of filling can be programmed separately. The performance of this pump system was tested in experiments on 15 cross-circulated hearts and proved satisfactory for precise analysis of the instantaneous pressure-volume relation in the ventricle.

Entities:  

Mesh:

Year:  1977        PMID: 596471     DOI: 10.1152/ajpheart.1977.233.6.H718

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  11 in total

Review 1.  Comparison of the Gibbs and Suga formulations of cardiac energetics: the demise of "isoefficiency".

Authors:  J-C Han; A J Taberner; K Tran; S Goo; D P Nickerson; M P Nash; P M F Nielsen; E J Crampin; D S Loiselle
Journal:  J Appl Physiol (1985)       Date:  2012-08-09

2.  Development and use of a remote-controlled mitral valve.

Authors:  J S Meisner; S Nikolić; T Tamura; K Tamura; R W Frater; E L Yellin
Journal:  Ann Biomed Eng       Date:  1986       Impact factor: 3.934

3.  Extracardiac pressure changes do not alter contractile function of the isolated left ventricle.

Authors:  M G Midei; W L Maughan; R Y Oikawa; D A Kass; K Sagawa
Journal:  Ann Biomed Eng       Date:  1987       Impact factor: 3.934

4.  A simple acoustic displacement transducer system.

Authors:  K Sunagawa; K Sagawa; K O Lim
Journal:  Med Biol Eng Comput       Date:  1984-01       Impact factor: 2.602

5.  Mechanoelectrical feedback: independent role of preload and contractility in modulation of canine ventricular excitability.

Authors:  B B Lerman; D Burkhoff; D T Yue; M R Franz; K Sagawa
Journal:  J Clin Invest       Date:  1985-11       Impact factor: 14.808

6.  Mechanical efficiency of the left ventricle as a function of preload, afterload, and contractility.

Authors:  H Suga; Y Igarashi; O Yamada; Y Goto
Journal:  Heart Vessels       Date:  1985-02       Impact factor: 2.037

7.  Microprocessor control of a ventricular volume servo-pump.

Authors:  K Sunagawa; K O Lim; D Burkhoff; K Sagawa
Journal:  Ann Biomed Eng       Date:  1982       Impact factor: 3.934

8.  Effects of pentobarbital on inotropic state of isolated canine left ventricle.

Authors:  D S Snyder; Y Harasawa; K Sagawa; W C Hunter
Journal:  Heart Vessels       Date:  1993       Impact factor: 2.037

Review 9.  Effect of a bradycardic agent on the isolated blood-perfused canine heart.

Authors:  J D Schipke; Y Harasawa; S Sugiura; J Alexander; D Burkhoff
Journal:  Cardiovasc Drugs Ther       Date:  1991-04       Impact factor: 3.727

10.  In vitro studies of isolated supported human hearts.

Authors:  D Burkhoff; J T Flaherty; D T Yue; A Herskowitz; R Y Oikawa; S Sugiura; M R Franz; W A Baumgartner; J Schaefer; B A Reitz
Journal:  Heart Vessels       Date:  1988       Impact factor: 2.037

View more