Literature DB >> 5927020

Evaluation of filters for removal of bacteriophages from air.

C J Washam, C H Black, W E Sandine, P R Elliker.   

Abstract

Glass wool, nonabsorbent cotton, fiberglass filter medium, and a commercial absolute filter were tested for effectiveness in removing aerosolized bacterial viruses under low flow rate (1 ft(3)/min) and high flow rate (10 to 25 ft(3)/min) air-flow conditions. Special equipment was designed for measurement of filter efficiencies under the two air-flow conditions. Under low air-flow rate test conditions, glass wool was only 98.543 to 99.83% efficient, whereas cotton (five layers), fiberglass medium (three layers), and the commercial absolute filter were at least 99.900, 99.999, and 99.999 efficient, respectively. Glass wool and cotton were not used under higher air-flow conditions because they were difficult to assemble in leak-tight filters. The commercial absolute filter and fiberglass medium (three layers) were at least 99.990 and 99.999% efficient, respectively, under the higher air flow conditions. A stainless-steel filter of simple design and fitted with three layers of fiberglass medium was found to be greater than 99.999% efficient in removing high concentrations (20,000 to 70,000 plaque-forming units per cubic foot) of aerosolized bacteriophages from air moving at a low flow rate (1 ft(3)/min). Use of this filter on pressure-vacuum tanks in the fermentation industry is suggested. Several other uses of such a filter are proposed.

Entities:  

Mesh:

Year:  1966        PMID: 5927020      PMCID: PMC546768          DOI: 10.1128/am.14.4.497-505.1966

Source DB:  PubMed          Journal:  Appl Microbiol        ISSN: 0003-6919


  5 in total

1.  TESTING AIR-FILTERING SYSTEMS. I. PROCEDURE FOR TESTING HIGH-EFFICIENCY AIR FILTERS ON EXHAUST SYSTEMS.

Authors:  J R SONGER; J F SULLIVAN; J W HURD
Journal:  Appl Microbiol       Date:  1963-09

2.  New sampler for the collection, sizing, and enumeration of viable airborne particles.

Authors:  A A ANDERSEN
Journal:  J Bacteriol       Date:  1958-11       Impact factor: 3.490

3.  Air hygiene for hospitals. II. Efficiency of fibrous filters against staphylococcic droplet nuclei and bacteria-bearing dust.

Authors:  H F ALLEN
Journal:  J Am Med Assoc       Date:  1959-05-16

4.  Spun glass air filters for bacteriological cabinets, animal cages, and shaking machine containers.

Authors:  H M DECKER; F A GEILE; J B HARSTAD; N H GROSS
Journal:  J Bacteriol       Date:  1952-03       Impact factor: 3.490

5.  Lightweight, high-volume electrostatic precipitator survey sampler.

Authors:  M Lippmann; H J Di Giovanni; S Cravitt; P Lilienfeld
Journal:  Am Ind Hyg Assoc J       Date:  1965 Sep-Oct
  5 in total
  4 in total

1.  Model system using coliphage phi X174 for testing virus removal by air filters.

Authors:  M L Rapp; T Thiel; R J Arrowsmith
Journal:  Appl Environ Microbiol       Date:  1992-03       Impact factor: 4.792

2.  Bacteriophage aerosol challenge of installed air contamination control systems.

Authors:  M M Jensen
Journal:  Appl Microbiol       Date:  1967-11

3.  Evaluation of a commercial air filter for removal of viruses from the air.

Authors:  P Roelants; B Boon; W Lhoest
Journal:  Appl Microbiol       Date:  1968-10

Review 4.  The use of mesophilic cultures in the dairy industry.

Authors:  C Daly
Journal:  Antonie Van Leeuwenhoek       Date:  1983-09       Impact factor: 2.271

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.