Literature DB >> 572542

Observations on the validity of using "NEN-TRAC" microspheres for measuring organ blood flow.

J R Hales, R B King, A A Fawcett.   

Abstract

"NEN-TRAC" brand of radioactive microsphere, 15 micron in diameter, have recently become available and therefore organ blood flow (Q) values obtained using these have been compared with values simultaneously obtained with the well-established "TRACER" brand of microspheres. For all major tissues of the body of two conscious sheep, there was excellent agreement between Q values obtained using NEN-TRAC Ce-141 and TRACER Sr-85 in one sheep, and between Q values obtained using NEN-TRAC Ce-141 and Sn-113 and TRACER Cr-51, Sr-85 and Nb-95 in a second sheep. It is concluded that NEN-TRAC microspheres satisfy the major validation tests to which TRACER microspheres have been previously subjected, and therefore it is valid to proceed with use of the new product.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 572542     DOI: 10.1007/bf00581435

Source DB:  PubMed          Journal:  Pflugers Arch        ISSN: 0031-6768            Impact factor:   3.657


  4 in total

1.  Blood flow measurements with radionuclide-labeled particles.

Authors:  M A Heymann; B D Payne; J I Hoffman; A M Rudolph
Journal:  Prog Cardiovasc Dis       Date:  1977 Jul-Aug       Impact factor: 8.194

2.  The circulation of the fetus in utero. Methods for studying distribution of blood flow, cardiac output and organ blood flow.

Authors:  A M Rudolph; M A Heymann
Journal:  Circ Res       Date:  1967-08       Impact factor: 17.367

3.  Measure- ment of distribution of cardiac output.

Authors:  S Kaihara; P D Van Heerden; T Migita; H N Wagner
Journal:  J Appl Physiol       Date:  1968-12       Impact factor: 3.531

4.  Direct observations of the behaviour of microspheres in microvasculature.

Authors:  J R Hales; W J Cliff
Journal:  Bibl Anat       Date:  1977
  4 in total
  4 in total

Review 1.  Blood flow distributions by microsphere deposition methods.

Authors:  F W Prinzen; J B Bassingthwaighte
Journal:  Cardiovasc Res       Date:  2000-01-01       Impact factor: 10.787

2.  Regional blood flow in genetically obese (ob/ob) mice. The importance of brown adipose tissue to the reduced energy expenditure on non-shivering thermogenesis.

Authors:  P L Thurlby; P Trayhurn
Journal:  Pflugers Arch       Date:  1980-06       Impact factor: 3.657

3.  Influence of noradrenaline on blood flow to brown adipose tissue in rats exhibiting diet-induced thermogenesis.

Authors:  N J Rothwell; M J Stock
Journal:  Pflugers Arch       Date:  1981-03       Impact factor: 3.657

4.  The effects of perfusion conditions on melphalan distribution in the isolated perfused rat hindlimb bearing a human melanoma xenograft.

Authors:  Z Y Wu; B M Smithers; P G Parsons; M S Roberts
Journal:  Br J Cancer       Date:  1997       Impact factor: 7.640

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.