Literature DB >> 568254

A video-angiometer for simultaneous and continuous measurement of inner and outer vessel diameters. Technical report.

R Assmann, H Henrich.   

Abstract

A system is described for continuously measuring vessel diameters. It bases on the evaluation of video signal differences of a video camera which are induced by light intensity differences (grey levels) caused by the vascular wall structures. The system is electronically linear, automatically measuring and in addition eyeball controlled by the human sensor: the inaccuracy does not exceed the 5% level.

Entities:  

Mesh:

Year:  1978        PMID: 568254     DOI: 10.1007/bf00584961

Source DB:  PubMed          Journal:  Pflugers Arch        ISSN: 0031-6768            Impact factor:   3.657


  9 in total

1.  CONTINUOUS RECORDING OF ARTERIOLAR DIMENSIONS WITH A TELEVISION MICROSCOPE.

Authors:  C A WIEDERHIELM
Journal:  J Appl Physiol       Date:  1963-09       Impact factor: 3.531

2.  Histometrical investigations of arteries in reference to arterial hypertension.

Authors:  M FURUYAMA
Journal:  Tohoku J Exp Med       Date:  1962-05-25       Impact factor: 1.848

3.  Microvascular measurements by video image shearing and splitting.

Authors:  M Intaglietta; W R Tompkins
Journal:  Microvasc Res       Date:  1973-05       Impact factor: 3.514

4.  On-line measurement of microvascular dimensions by television microscopy.

Authors:  M Intaglietta; W R Tompkins
Journal:  J Appl Physiol       Date:  1972-04       Impact factor: 3.531

5.  Optical scanning photometry for microcirculatory studies.

Authors:  H Wayland; P C Johnson
Journal:  Bibl Anat       Date:  1969

6.  A new video-angiometer device for on-line measurement of diameters in microvessels.

Authors:  R Assmann; H Henrich
Journal:  Bibl Anat       Date:  1977

7.  Recording of microvascular dimensions with an image-splitter television microscope.

Authors:  S Baez
Journal:  J Appl Physiol       Date:  1966-01       Impact factor: 3.531

8.  Measurement of microvascular dimensions in vivo.

Authors:  P C Johnson
Journal:  J Appl Physiol       Date:  1967-10       Impact factor: 3.531

9.  Structural differences in the mesentery microcirculation between normotensive and spontaneously hypertensive rats.

Authors:  H Henrich; R Hertel; R Assmann
Journal:  Pflugers Arch       Date:  1978-07-18       Impact factor: 3.657

  9 in total
  3 in total

1.  Changes of diameter and length in cylindrical segments of canine femoral arteries during activation at different pressures.

Authors:  W Wiegand; K Golenhofen
Journal:  Pflugers Arch       Date:  1987-07       Impact factor: 3.657

2.  Sensitive force transducer system for mechanical studies of single isolated vascular smooth muscle cells.

Authors:  P A Wieringa; M van der Meer; A M VanDijk; J D Laird
Journal:  Med Biol Eng Comput       Date:  1984-03       Impact factor: 2.602

3.  Mechanical behavior of pressurized in vitro prearteriolar vessels determined with a video system.

Authors:  W Halpern; G Osol; G S Coy
Journal:  Ann Biomed Eng       Date:  1984       Impact factor: 3.934

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.