Literature DB >> 567107

Postoperative dislocation after Charnley low-friction arthroplasty.

A Etienne, Z Cupic, J Charnley.   

Abstract

The dislocation rate after the Charnley arthroplasty with the 22 mm diameter femoral head was 0.8% in 3,820 arthroplasties performed before 1971. Over this era the annual rate ranged from 0.5% to 1.4% without any apparent explanation. Following the routine use of a low position for the socket in the acetabulum and the Long Posterior Wall design of socket, the dislocation rate fell to 0.4% over 4,706 arthroplasties and the annual dislocation rate over 4 years ranged between 0.5% and 0.2%.

Entities:  

Mesh:

Year:  1978        PMID: 567107

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  15 in total

1.  Acetabular component positioning using anatomic landmarks of the acetabulum.

Authors:  Yong-Chan Ha; Jeong Joon Yoo; Young-Kyun Lee; Jin Young Kim; Kyung-Hoi Koo
Journal:  Clin Orthop Relat Res       Date:  2012-07-10       Impact factor: 4.176

2.  A cadaveric study of posterior dislocation after total hip replacement-effects of head diameter and acetabular anteversion.

Authors:  Fu Yuen Ng; Jiang Tao Zhang; Kwong Yuen Chiu; Chun Hoi Yan
Journal:  Int Orthop       Date:  2010-02-24       Impact factor: 3.075

3.  Structural changes in the socket of a Charnley low friction arthroplasty associated with recurrent subluxation.

Authors:  B M Wroblewski; J P Hodgkinson; B Maltby
Journal:  Int Orthop       Date:  1989       Impact factor: 3.075

4.  Is an algorithmic approach to the treatment of recurrent dislocation after THA effective?

Authors:  Ehsan Saadat; Glenn Diekmann; Steven Takemoto; Michael D Ries
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

5.  The hip cast-brace for hip prosthesis instability.

Authors:  H D Stewart
Journal:  Ann R Coll Surg Engl       Date:  1983-11       Impact factor: 1.891

6.  [Apropos of 87 dislocations of total hip prostheses].

Authors:  B Courtois; R Variel; J Le Saout; B Kerboul; C Lefèvre
Journal:  Int Orthop       Date:  1985       Impact factor: 3.075

7.  [Dynamic stabilization of a total hip arthroplasty. Apropos of 100 total prostheses of which 52 dislocations].

Authors:  D Fontes; R Didry; A Lortat-Jacob; J Benoit
Journal:  Int Orthop       Date:  1990       Impact factor: 3.075

8.  Late dislocation after total hip arthroplasty.

Authors:  R M D Meek; D B Allan; G McPhillips; L Kerr; C R Howie
Journal:  Clin Med Res       Date:  2008-05

9.  The effect of posterior capsule repair upon post-operative hip dislocation following primary total hip arthroplasty.

Authors:  Shang-Ju Tsai; Chen-Ti Wang; Ching-Chuan Jiang
Journal:  BMC Musculoskelet Disord       Date:  2008-02-29       Impact factor: 2.362

10.  Head size and dislocation rate in primary total hip arthroplasty.

Authors:  Somesh P Singh; Haresh P Bhalodiya
Journal:  Indian J Orthop       Date:  2013-09       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.