Literature DB >> 5602577

Diagnosis of haemophilia: use of an artificial factor-VIII-deficient human plasma system.

E M Essien, G I Ingram.   

Abstract

An artificial clotting system deficient in factor VIII has been made from normal human plasma. Factors XII and XI are supplied as ;activation product'. An eluate from Al(OH)(3), which has been incubated with normal plasma, supplies factors X and IX in their ;plasma' (unactivated) form with II. Factor V is provided as the supernatant after the Al(OH)(3)- treated plasma has been precipitated at one-third saturation with (NH(4))(2)SO(4). Fibrinogen is freed of factor VIII by freezing and thawing a lyophylized preparation and then added. Of these, activation product and the fibrinogen may be prepared in advance and stored frozen, and the eluate and supernatant may be made on the day of testing. A phospholipid source and CaCl(2)-solution are also required. In use, a patient's and a control plasma are first diluted in a mixture of the eluate, supernatant, and fibrinogen solution, and clotting times are recorded after completing the system by adding the phospholipid, activation product, and calcium chloride. The clotting times from the mixtures containing the patient's and the control plasmas may then be compared.

Entities:  

Mesh:

Substances:

Year:  1967        PMID: 5602577      PMCID: PMC473522          DOI: 10.1136/jcp.20.4.620

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  5 in total

1.  HIGH-POTENCY ANTIHAEMOPHILIC FACTOR CONCENTRATE PREPARED FROM CRYOGLOBULIN PRECIPITATE.

Authors:  J G POOL; E J GERSHGOLD; A R PAPPENHAGEN
Journal:  Nature       Date:  1964-07-18       Impact factor: 49.962

2.  THROMBIN AND THE INTERACTION OF FACTORS 8 AND 9.

Authors:  R BIGGS; R G MACFARLANE; K W DENSON; B J ASH
Journal:  Br J Haematol       Date:  1965-05       Impact factor: 6.998

3.  THE AGGREGATION OF HUMAN PLATELETS BY BACTERIAL ENDOTOXIN.

Authors:  V J REAM; D DEYKIN; V GUREWICH; S WESSLER
Journal:  J Lab Clin Med       Date:  1965-08

4.  PARTIAL THROMBOPLASTIN TIME TEST WITH KAOLIN. NORMAL RANGE AND MODIFICATIONS FOR THE DIAGNOSIS OF HAEMOPHILIA AND CHRISTMAS DISEASE.

Authors:  M O MATCHETT; G I INGRAM
Journal:  J Clin Pathol       Date:  1965-07       Impact factor: 3.411

5.  Partial thromboplastin time test with kaolin: diagnosis of haemophilia and Christmas disease without natural reference plasmas.

Authors:  S F Knights; G I Ingram
Journal:  J Clin Pathol       Date:  1967-07       Impact factor: 3.411

  5 in total
  1 in total

1.  Preparation of 'contact product' as a reagent for coagulation tests.

Authors:  J L Pérez-Requejo; G I Ingram
Journal:  J Clin Pathol       Date:  1975-07       Impact factor: 3.411

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.