Literature DB >> 558064

A turbidimetric immuno assay (TIA) with automated individual blank compensation.

P J Van Munster, G E Hoelen, M Samwel-Mantingh, M Holtman-Van Meurs.   

Abstract

A simple and sensitive turbidimtric immunoassay (TIA) has been described. The automated method has been based on the use of the LKB reaction rate analyser, an instrument that is already present in many clinical chemical laboratories. The precipitin reaction is accelerated and enhanced by poly-ethylene glycol 6000 at a concentration of 50 g/l. Sample volume 2--100 micronl. Use of antiserum: 3--15 micronl per test. Sampling rate 30--60 samples per hour. The choice and the usefulness if antisera is discussed. The major advantage of the present method is the individual measurement and compensation for the initial absorbance (340 nm) immediately after the mixing of antigen and antiserum. This enables the determination of very low serum protein concentrations (from 0.005 mg/ml) which is not possible with other methods that require separate blank determinations. The turbidity course is different in antigen and antibody excess. The The chance of misinterpretation is small. The precision of the method is satisfactory. Within-run precision is 1--2% (C.V.) in the IgA/anti-alpha-system. Between-run-precision in the IgM/anti-micron system: 3.9% (C.V.). The day-to-day precision for IgG, IgA and IgM determinations resulting from a 7-month period of quality control was found to be 6.1% and 10.5%, respectively. RID and TIA methods agree very well. IgM determinations in cord serum from 104 newborns revealed a mean value and standard deviation of 14.6 +/- 6.3 I.U./ml (0.13 +/- 0.06 mg/ml).

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 558064     DOI: 10.1016/0009-8981(77)90165-6

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  4 in total

1.  Complement activation and neutrophil dysfunction in burned patients with sepsis--a study of two cases.

Authors:  J Utoh; T Utsunomiya; T Imamura; H Katsuya; Y Miyauchi; T Kambara
Journal:  Jpn J Surg       Date:  1989-07

2.  Complement conversion and leukocyte kinetics in open heart surgery.

Authors:  J Utoh; T Yamamoto; T Kambara; H Goto; Y Miyauchi
Journal:  Jpn J Surg       Date:  1988-05

3.  Antibody responses in vivo in chromosome instability syndromes with immunodeficiency.

Authors:  C M Weemaes; T H The; P J van Munster; J A Bakkeren
Journal:  Clin Exp Immunol       Date:  1984-09       Impact factor: 4.330

4.  Recovery of immune function after cessation of maintenance therapy in acute lymphoblastic leukemia (ALL) of childhood.

Authors:  G A de Vaan; P J van Munster; J A Bakkeren
Journal:  Eur J Pediatr       Date:  1982-10       Impact factor: 3.183

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.