Literature DB >> 5565518

Leakage of oxygen from blood and water samples stored in plastic and glass syringes.

P V Scott, J N Horton, W W Mapleson.   

Abstract

Theory and experiment showed that samples of blood and water stored in 2-ml and 5-ml syringes made of polypropylene, polystyrene, or S.A.N. co-polymer exchanged oxygen with their surroundings. In the first hour the exchange was due mainly to equilibration with the plastic of the syringe and only in small degree to permeation through the plastic. With high initial tension or with blood of low haemoglobin concentration the exchange can result in errors in Po(2) of up to 6% in two minutes and 16% in 30 to 60 minutes. With all-glass syringes the exchange was much slower but, even so, after 24 hours was important in all but a few of 18 interchangeable glass syringes. Therefore unless analysis can be started immediately all-glass syringes are to be preferred, and for prolonged storage even these should be selected.

Entities:  

Mesh:

Substances:

Year:  1971        PMID: 5565518      PMCID: PMC1800464          DOI: 10.1136/bmj.3.5773.512

Source DB:  PubMed          Journal:  Br Med J        ISSN: 0007-1447


  11 in total

1.  O2 SOLUBILITY IN BLOOD AND TEMPERATURE CORRECTION FACTORS FOR PO2.

Authors:  J HEDLEY-WHYTE; M B LAVER
Journal:  J Appl Physiol       Date:  1964-09       Impact factor: 3.531

2.  The disappearance of oxygen from shed blood at body temperature.

Authors:  E ASMUSSEN; M NIELSEN
Journal:  Scand J Clin Lab Invest       Date:  1961       Impact factor: 1.713

3.  CONTINUOUS INTRA-ARTERIAL PO2 IN NORMAL MAN USING A FLEXIBLE MICROELECTRODE.

Authors:  G CHARLTON; D READ; J READ
Journal:  J Appl Physiol       Date:  1963-11       Impact factor: 3.531

4.  Effect of syringe material on oxygen tension in stored blood.

Authors:  H Hilty; B Karendal
Journal:  Acta Soc Med Ups       Date:  1969

5.  The response pattern of polarographic oxygen electrodes and its influence on linearity and hysteresis.

Authors:  W W Mapleson; J N Horton; W S Ng; D D Imrie
Journal:  Med Biol Eng       Date:  1970-11

6.  The handling of xenon-133 in clinical studies.

Authors:  A D LeBlanc; P C Johnson
Journal:  Phys Med Biol       Date:  1971-01       Impact factor: 3.609

7.  Blood gas calculator.

Authors:  J W Severinghaus
Journal:  J Appl Physiol       Date:  1966-05       Impact factor: 3.531

8.  Digital computer subroutine for the conversion of oxygen tension into saturation.

Authors:  G R Kelman
Journal:  J Appl Physiol       Date:  1966-07       Impact factor: 3.531

9.  Effect of sampling technique on the determination of PaO2, during oxygen breathing.

Authors:  G Fletcher; J L Barber
Journal:  J Appl Physiol       Date:  1966-03       Impact factor: 3.531

10.  pH and blood-gas analysis. Methods of measurement and sources of error using electrode systems.

Authors:  A P Adams; J O Morgan-Hughes; M K Sykes
Journal:  Anaesthesia       Date:  1967-10       Impact factor: 6.955

View more
  7 in total

Review 1.  Continuous intra-arterial blood gas monitoring.

Authors:  B Venkatesh; S P Hendry
Journal:  Intensive Care Med       Date:  1996-08       Impact factor: 17.440

2.  [Coronary reserve capacity and maximum oxygen consumption of the human heart].

Authors:  M Tauchert
Journal:  Basic Res Cardiol       Date:  1973 Mar-Apr       Impact factor: 17.165

3.  Is it necessary to transport arterial blood samples on ice for pH and gas analysis?

Authors:  A A Nanji; K J Whitlow
Journal:  Can Anaesth Soc J       Date:  1984-09

4.  In vitro Gd-DTPA relaxometry studies in oxygenated venous human blood and aqueous solution at 3 and 7 T.

Authors:  Chaitanya Kalavagunta; Shalom Michaeli; Gregory J Metzger
Journal:  Contrast Media Mol Imaging       Date:  2014 Mar-Apr       Impact factor: 3.161

5.  [The measurement of pH and gases in the blood using microanalysis: the effect of storage at 4 degrees C for an hour. A study in the rat].

Authors:  J H Gaudy; J F Sicard; M Quignon
Journal:  Can J Anaesth       Date:  1992-10       Impact factor: 5.063

6.  Effects of sample storage time, temperature and syringe type on blood gas tensions in samples with high oxygen partial pressures.

Authors:  J J Pretto; P D Rochford
Journal:  Thorax       Date:  1994-06       Impact factor: 9.139

7.  Glass syringes are better than plastic for preserving arterial blood gas for oxygen partial pressure determination: an explanation based on nanomaterial composition.

Authors:  Viroj Wiwanitkit
Journal:  Int J Nanomedicine       Date:  2006
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.