Bipolar fixation of fractures of the distal end of the radius.

A Rauïs, A Ledoux, A Thiebaut, M van der Ghinst.   

Abstract

The frequency fo secondary displacement in fractures of the distal end of the radius is very high and varies from 40 to 60% in various series. This results from the void in the epiphysis after reduction due to crushing of the cancellous bone. Secondary displacement can be easily avoided by the bipolar fixation method. This method is quite simple. Two strong Kirschner wires are driven into the radius and into the first metacarpal, and then incorporated in the cast after the reduction of the fracture. In this study we have followed 102 out of 250 patients treated by this method. The number of secondary displcements has been negligible. The functional results are excellent and we did not find any untoward effects attributable to our technique.

Entities:  

Mesh:

Year:  1979        PMID: 548502     DOI: 10.1007/BF00266877

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  11 in total

1.  [RECENT FRACTURES OF THE LOWER EXTREMITY OF THE RADIUS IN ADULTS].

Authors:  J CASTAING
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1964 Sep-Oct

2.  Long-term follow-up of treatment of comminuted fractures of the distal end of the radius by transfixation with Kirschner wires and cast.

Authors:  M SCHECK
Journal:  J Bone Joint Surg Am       Date:  1962-03       Impact factor: 5.284

3.  Fractures of the distal end of the radius. A clinical and statistical study of end results.

Authors:  A LIDSTROM
Journal:  Acta Orthop Scand Suppl       Date:  1959

4.  Colles' fracture; a study of two thousand cases from the New York State Workmen's Compensation Board.

Authors:  R W BACORN; J F KURTZKE
Journal:  J Bone Joint Surg Am       Date:  1953-07       Impact factor: 5.284

5.  [Treatment of comminuted fractures of the distal end of the radius by traction using transfixing Kirschner's wires and plaster cast].

Authors:  P Cartier; J Tiesse; C H Père
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1975-09

6.  [Fixation of fractures of the distal radius].

Authors:  A Ledoux; A Rauis; M Van der Ghinst
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1973 Jul-Aug

7.  Fracture of the distal radius including sequelae--shoulder-hand-finger syndrome, disturbance in the distal radio-ulnar joint and impairment of nerve function. A clinical and experimental study.

Authors:  G Frykman
Journal:  Acta Orthop Scand       Date:  1967

8.  [Consolidation in an incorrect position of fractures of the distal end of the radius. Anatomical, etiological and therapeutic considerations].

Authors:  A Ledoux
Journal:  Acta Chir Belg       Date:  1969-10       Impact factor: 1.090

9.  [Stabilization of the lower radial epiphysis by double radiocubital fixation].

Authors:  P Ectors; A Danis
Journal:  Acta Orthop Belg       Date:  1968 Jul-Aug       Impact factor: 0.500

10.  [Sequelae of fractures of the lower end of the radius. Their causes and treatments].

Authors:  A de Wulf; J P Razemon
Journal:  Acta Orthop Belg       Date:  1968 Jan-Feb       Impact factor: 0.500

View more
  2 in total

1.  The external fixateur in the management of unstable Colles' fracture.

Authors:  M Forgon; E Mammel
Journal:  Int Orthop       Date:  1981       Impact factor: 3.075

2.  Comminuted Colles' fractures treated with external fixation.

Authors:  J Kongsholm; C Olerud
Journal:  Arch Orthop Trauma Surg       Date:  1987
  2 in total