Literature DB >> 539549

Applicability of activated carbon felt to the dosimetry of solvent vapor mixture.

T Hirayama, M Ikeda.   

Abstract

Affirmative results were obtained to prove that diffusion-absorption on carbon-desorption dosimetry is applicable to monitor exposure to mixed vapors of organic solvents (n-hexane:ethyl acetate:toluene=1:4:1). While most of seven carbon felt preparations tested failed to absorb n-hexane in humid air or the amounts absorbed were no longer proportional to vapor concentrations even in dry air when the sum of the three vapor concentrations were over 3 times workroom threshold limits, two preparations revealed capacity to absorb n-hexane even in the air with relative humidity of 95%. Furthermore, the amounts absorbed during four hour exposures were linearly related to the vapor concentrations of at least 4.5 times workroom threshold limits when the three vapor concentrations were summed up, and, at lower concentrations, the absorbed amounts were proportional to the exposure duration of up to eight hours. Short term peak exposure could also be detected; the ratio between the observed and the expected was about 80% at lowest.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 539549     DOI: 10.1080/15298667991430749

Source DB:  PubMed          Journal:  Am Ind Hyg Assoc J        ISSN: 0002-8894


  45 in total

1.  Diffusive personal sampler for methyl acetate monitoring.

Authors:  T Yasugi; T Kawai; K Mizunuma; M Ikeda
Journal:  Bull Environ Contam Toxicol       Date:  1992-09       Impact factor: 2.151

2.  Absence of blue-yellow color vision loss among workers exposed to toluene or tetrachloroethylene, mostly at levels below occupational exposure limits.

Authors:  H Nakatsuka; T Watanabe; Y Takeuchi; N Hisanaga; E Shibata; H Suzuki; M Y Huang; Z Chen; Q S Qu; M Ikeda
Journal:  Int Arch Occup Environ Health       Date:  1992       Impact factor: 3.015

3.  Comparative evaluation of urinalysis and blood analysis as means of detecting exposure to organic solvents at low concentrations.

Authors:  T Kawai; T Yasugi; K Mizunuma; S Horiguchi; H Iguchi; Y Uchida; O Iwami; M Ikeda
Journal:  Int Arch Occup Environ Health       Date:  1992       Impact factor: 3.015

4.  The method of choice for the determination of 2,5-hexanedione as an indicator of occupational exposure to n-hexane.

Authors:  T Kawai; K Mizunuma; T Yasugi; Y Uchida; M Ikeda
Journal:  Int Arch Occup Environ Health       Date:  1990       Impact factor: 3.015

5.  Exposure to vapors of benzene and other aromatic solvents in tank truck loading and delivery.

Authors:  T Kawai; K Yamaoka; Y Uchida; M Ikeda
Journal:  Bull Environ Contam Toxicol       Date:  1991-01       Impact factor: 2.151

6.  Evaluation of biomarkers of occupational exposure to toluene at low levels.

Authors:  Toshio Kawai; Hirohiko Ukai; Osamu Inoue; Yuki Maejima; Yoshinari Fukui; Fumiko Ohashi; Satoru Okamoto; Shiro Takada; Haruhiko Sakurai; Masayuki Ikeda
Journal:  Int Arch Occup Environ Health       Date:  2007-10-13       Impact factor: 3.015

7.  Occupational dimethylformamide exposure. 3. Health effects of dimethylformamide after occupational exposure at low concentrations.

Authors:  S X Cai; M Y Huang; L Q Xi; Y L Li; J B Qu; T Kawai; T Yasugi; K Mizunuma; T Watanabe; M Ikeda
Journal:  Int Arch Occup Environ Health       Date:  1992       Impact factor: 3.015

8.  Excretion of methylhippuric acids in urine of workers exposed to a xylene mixture: comparison among three xylene isomers and toluene.

Authors:  O Inoue; K Seiji; T Kawai; T Watanabe; C Jin; S X Cai; Z Chen; Q S Qu; T Zhang; M Ikeda
Journal:  Int Arch Occup Environ Health       Date:  1993       Impact factor: 3.015

9.  Monitoring of workers exposed to a mixture of toluene, styrene and methanol vapours by means of diffusive air sampling, blood analysis and urinalysis.

Authors:  T Kawai; T Yasugi; K Mizunuma; S Horiguchi; I Morioka; K Miyashita; Y Uchida; M Ikeda
Journal:  Int Arch Occup Environ Health       Date:  1992       Impact factor: 3.015

10.  Comparative evaluation of blood and urine analysis as a tool for biological monitoring of n-hexane and toluene.

Authors:  T Kawai; T Yasugi; K Mizunuma; S Horiguchi; M Ikeda
Journal:  Int Arch Occup Environ Health       Date:  1993       Impact factor: 3.015

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.