Determination of arterial blood flow by percutaneously introduced flow sensors in an external magnetic field. II. Implementation of the method in vivo.

A Kolin, J H Grollman, R J Steckel, H D Snow.   

Abstract

Blood flow in a dog's aorta has been measured by percutaneous introduction of a flow sensor. Two types of flow probes have been used in conjunction with an external magnetic field: Loop-shaped probes used as rate of volume-flow meters and L-shaped probes as velometers. Methods of calibration and establishing the base line are discussed, and the performance of the apparatus is illustrated by records of blood flow in the thoracic and abdominal regions of the aorta.

Entities:  

Mesh:

Substances:

Year:  1971        PMID: 5276298      PMCID: PMC391095          DOI: 10.1073/pnas.68.1.29

Source DB:  PubMed          Journal:  Proc Natl Acad Sci U S A        ISSN: 0027-8424            Impact factor:   11.205


  3 in total

1.  Effects of the vessel wall on electromagnetic flow measurement.

Authors:  U GESSNER
Journal:  Biophys J       Date:  1961-11       Impact factor: 4.033

2.  Determination of arterial blood flow by percutaneously introduced flow sensors in an external magnetic field. I. The method.

Authors:  A Kolin; J H Grollman; R J Steckel; H D Snow
Journal:  Proc Natl Acad Sci U S A       Date:  1970-12       Impact factor: 11.205

3.  A new approach to electromagnetic blood flow determination by means of catheter in an external magnetic field.

Authors:  A Kolin
Journal:  Proc Natl Acad Sci U S A       Date:  1970-03       Impact factor: 11.205

  3 in total
  4 in total

1.  Extracorporeal magnet perivascular electromagnetic flow meters.

Authors:  A Kolin; J R Steele; J S Imai; R N MacAlpin; I R Coster; H D Snow
Journal:  Pflugers Arch       Date:  1976-04-06       Impact factor: 3.657

2.  External field electromagnetic measurement of blood flow. An alternative approach to the solution of the baseline problem.

Authors:  A Kolin; R N MacAlpin; H D Snow; M W Lenz
Journal:  Pflugers Arch       Date:  1972       Impact factor: 3.657

3.  A constant-field interrupted resonance system for percutaneous electromagnetic measurement of blood flow.

Authors:  A Kolin; J R Steele; J S Imai; R N Macalpin
Journal:  Proc Natl Acad Sci U S A       Date:  1974-04       Impact factor: 11.205

Review 4.  Blood flow and blood velocity measurement in vivo by electromagnetic induction.

Authors:  D G Wyatt
Journal:  Med Biol Eng Comput       Date:  1984-05       Impact factor: 2.602

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.