Literature DB >> 526569

Analysis of tyrosine and deuterium labelled tyrosine in tissues and body fluids.

B Sjöquist.   

Abstract

A gas chromatographic mass spectrometric method has been developed to determine tyrosine and deuterium labelled tyrosine in biological samples using alpha-methyltyrosine (alpha-Me Ty) or m-hydroxyphenylalanine as internal standards. With the latter standard both labelled and unlabelled tyrosine as well as alpha-Me Ty can be determined simultaneously, in for example human blood, following administration of alpha-Me Ty to inhibit catecholamine synthesis. After isolation of the amino acids on an ion exchange column (Amberlite IR 120) the butyl ester pentafluoropropionyl derivatives were prepared. In human plasma the precision of the method was determined at a level of 80 nmol tyrosine ml-1 and found to be +/- 5% (coefficient of variation, n = 10).

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 526569     DOI: 10.1002/bms.1200060905

Source DB:  PubMed          Journal:  Biomed Mass Spectrom        ISSN: 0306-042X


  1 in total

1.  Polarographic determination of metyrosine through treatment with nitrous acid.

Authors:  F A Aly; F Belal; A el-Brashy
Journal:  Pharm World Sci       Date:  1993-10-15