A gas chromatographic mass spectrometric chemical ionization assay for haloperidol with selected ion monitoring.

C L Hornbeck, J C Griffiths, R J Neborsky, M A Faulkner.   

Abstract

A new gas chromatographic mass spectrometric chemical ionization assay for haloperidol with selectedion monitoring is presented which provides for better combined selectivity and sensitivity than previous assays. Levels of haloperidol in 2 ml of human plasma were reproducibly measured down to subnanogram levels. Both methane and methane--ammonia chemical ionization spectra are presented for haloperidol and the internal standard trifluperidol.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 526559     DOI: 10.1002/bms.1200061004

Source DB:  PubMed          Journal:  Biomed Mass Spectrom        ISSN: 0306-042X