Literature DB >> 525309

Optical principles for estimation of endothelial cell density with the non-contact specular microscope.

T Olsen.   

Abstract

In non-contact specular microscopy of corneal endothelium, endothelial cell density is overestimated due to the angle of observation and the curvature of cornea. On the basis of theoretical considerations, it is concluded that if the angle of observation is kept at a small value the curvature of cornea contributes only insignificantly to this overestimation, the major determinant being the angle of observation. When an angle of 46 degrees is chosen between slit illumination and optical axis of the microscope it is calculated that estimates of endothelial cells should be multiplied with a factor of 0.959 to correct for the angle effect. Six eye were photographed with both a contact and non-contact specular microscope and endothelial cell density estimated. Mean observed difference in cell counts was +5.5% without correction and +1.2% with correction for angle effect. 95% confidence limits for the difference with correction were -3.7 and +6.0% respectively showing that estimates of endothelial cell density obtained with the non-contact specular microscope agree closely with those obtained by contact specular microscopy when corrected for angle of observation.

Mesh:

Year:  1979        PMID: 525309     DOI: 10.1111/j.1755-3768.1979.tb01853.x

Source DB:  PubMed          Journal:  Acta Ophthalmol (Copenh)        ISSN: 0001-639X


  5 in total

1.  Comparison of central corneal thickness and endothelial cell measurements by Scheimpflug camera system and two noncontact specular microscopes.

Authors:  Irmak Karaca; Suzan Guven Yilmaz; Melis Palamar; Halil Ates
Journal:  Int Ophthalmol       Date:  2017-07-03       Impact factor: 2.031

2.  Contact and noncontact specular microscopy.

Authors:  N C Price; H Cheng
Journal:  Br J Ophthalmol       Date:  1981-08       Impact factor: 4.638

3.  Non-contact specular microscopy of the normal corneal endothelium. A statistical evaluation of morphometric parameters.

Authors:  A Stefansson; O Müller; R Sundmacher
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1982       Impact factor: 3.117

4.  Studies on the development of extra-endothelial and intra-endothelial pigment deposits by means of direct and indirect contact specular microscopy of the cornea.

Authors:  C Hartmann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1982       Impact factor: 3.117

5.  Corneal endothelial cell density and morphology in normal Iranian eyes.

Authors:  Mohammad Nasser Hashemian; Sasan Moghimi; Masood Aghsaie Fard; Mohammad Reza Fallah; Mohammad Reza Mansouri
Journal:  BMC Ophthalmol       Date:  2006-03-06       Impact factor: 2.209

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.