| Literature DB >> 523966 |
E Nilsson, P Sundén, S Zetterquist.
Abstract
A simplified thermographic technique has been developed to provide continuous leg temperature profiles by manual scanning with a noncontactile infrared radiation transducer connected to a linera potentiometer for determination of the transducer position. The clinical value of the technique in the diagnosis of acute venous thromboses has been estimated in seventy patients and thirty controls, using plethysmography and phlebography as methods of reference. The thermographic diagnosis was based on side differences in temperature levels within different segments of the limbs, as calculated from the temperature profiles by means of planimetric technique. Standardized temperature profiles from the medial side of the limbs were found to demonstrate a side difference above the reference level in fifty-seven of fity-nine patients with acute venous thromboses, which means a diagnostic sensitivity corresponding to that of conventional thermography. Skin temperature profiles were superior to plethysmography, particularly in the diagnosis of thromboses located distally. Falsely positive results were obtained, as expected, in some cases of varicose veins or acute arthritis and skin infections. The presented type of thermography has obvious qualifications as a screening method in the early diagnosis of acute venous thromboses, being far less expensive but never the less more suited for objective numerical analyses and evaluation than conventional thermography with scanning cameras.Entities:
Mesh:
Year: 1979 PMID: 523966 DOI: 10.1080/00365517909106090
Source DB: PubMed Journal: Scand J Clin Lab Invest ISSN: 0036-5513 Impact factor: 1.713