Literature DB >> 513609

[Polyvinylpyrolidone-fixed hemoglobin as an oxygen carrying blood substitute (author's transl)].

K Schmidt.   

Abstract

The development of blood substitute oxygen carriers has branched off into several directions: stroma-free hemoglobin solutions, modelling of hemoglobin by fixation of heme or hemopeptides to polymers, filling of microcapsules with hemoglobin solution, crosslinking of hemoglobin. However, the application as blood replacement fluids in patients has not been possible so far because of several disadvantages. In this paper synthesis and properties of an oxygen carrying blood substitute are described in which the hemoglobin molecule is covalently bound to polyvinylpyrrolidone. In aqueous solution the preparation fulfills some basic requirements such as high solubility, only slightly increased oxygen affinity, and low viscosity. Normothermic perfusion experiments with isolated pig kidneys demonstrate that the solution provides an adequate oxygen supply to the organ, has no toxic side effects on kidney function, and has a significantly lower elimination rate compared to an unmodified hemoglobin solution.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 513609     DOI: 10.1007/bf01491757

Source DB:  PubMed          Journal:  Klin Wochenschr        ISSN: 0023-2173


  8 in total

1.  Acute oxygen supply by infusion of hemoglobin solutions.

Authors:  K Bonhard
Journal:  Fed Proc       Date:  1975-05

2.  DISC ELECTROPHORESIS. II. METHOD AND APPLICATION TO HUMAN SERUM PROTEINS.

Authors:  B J DAVIS
Journal:  Ann N Y Acad Sci       Date:  1964-12-28       Impact factor: 5.691

3.  DISC ELECTROPHORESIS. I. BACKGROUND AND THEORY.

Authors:  L ORNSTEIN
Journal:  Ann N Y Acad Sci       Date:  1964-12-28       Impact factor: 5.691

4.  Reversible oxygenation of heme bound to polyvinylpyridine and polyvinylimidazole.

Authors:  E Tsuchida; K Honda; H Sata
Journal:  Biopolymers       Date:  1974       Impact factor: 2.505

5.  Polyvinylpyrrolidone as a soluble carrier of proteins.

Authors:  B U von Specht; H Seinfeld; W Brendel
Journal:  Hoppe Seylers Z Physiol Chem       Date:  1973-12

6.  Blood gas calculator.

Authors:  J W Severinghaus
Journal:  J Appl Physiol       Date:  1966-05       Impact factor: 3.531

7.  Erythrocyte substitute for perfusion of brain.

Authors:  H A Sloviter; T Kamimoto
Journal:  Nature       Date:  1967-11-04       Impact factor: 49.962

8.  Evaluation of a stroma-free hemoglobin solution for use as a plasma expander.

Authors:  S F Rabiner; J R Helbert; H Lopas; L H Friedman
Journal:  J Exp Med       Date:  1967-12-01       Impact factor: 14.307

  8 in total
  1 in total

1.  From N-vinylpyrrolidone anions to modified paraffin-like oligomers via double alkylation with 1,8-dibromooctane: access to covalent networks and oligomeric amines for dye attachment.

Authors:  Daniela Obels; Melanie Lievenbrück; Helmut Ritter
Journal:  Beilstein J Org Chem       Date:  2016-07-06       Impact factor: 2.883

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.