[Application of the mechanical oscillator technique for the measurement of blood density and hematocrit (author's transl)].

H Hinghofer-Szalkay, T Kenner, H Leopold, H Holzer.   

Abstract

Density measurements were performed with an accuracy of 0.01 g/l by means of a density meter based on the "mechanical oscillator technique", on human whole blood, on plasma, and on erythrocyte concentrates. A highly significant correlation between blood density and hematocrit was found. If plasma and red cell densities are known, hematocrit can be estimated more precisely than using the centrifugation method. This fact is important if small variations of the hematocrit are to be determined. Such variations can be produced, e.g., by alteration of the transcapillary filtration equilibrium. Furthermore, the statistical distribution of plasma and erythrocyte densities allows to determine the range of variation of blood densities for certain hematocrit values and vice versa.

Entities:  

Mesh:

Year:  1979        PMID: 513608     DOI: 10.1007/bf01491756

Source DB:  PubMed          Journal:  Klin Wochenschr        ISSN: 0023-2173


  5 in total

1.  [The relation between the density of blood and the arterial pressure in animal experiments and in patients during hemodialysis (author's transl)].

Authors:  T Kenner; H Hinghofer-Szalkay; H Leopold; H Pogglitsch
Journal:  Z Kardiol       Date:  1977-07

2.  The application of the mechanical oscillator technique for the determination of the density of physiological fluids.

Authors:  H Leopold; R Jelinek; G P Tilz
Journal:  Biomed Tech (Berl)       Date:  1977-10       Impact factor: 1.411

3.  The continuous high-precision measurement of the density of flowing blood.

Authors:  T Kenner; H Leopold; H Hinghofer-Szalkay
Journal:  Pflugers Arch       Date:  1977-07-29       Impact factor: 3.657

4.  [Determination of the serum protein concentration based on the measurement of density by the mechanical oscillator technique (author's transl)].

Authors:  H Holzer; H Leopold; H Hinghofer-Szalkay; H Stübchen-Kirchner; E Maurer
Journal:  J Clin Chem Clin Biochem       Date:  1978-07

5.  [Rapid determination of the sedimentation rate of blood free from the influence of gravity (author's transl)].

Authors:  H Leopold; H Hinghofer-Szalkay; T Kenner; H Holzer
Journal:  Biomed Tech (Berl)       Date:  1978-05       Impact factor: 1.411

  5 in total
  1 in total

1.  [Investigations concerning postural influences on blood and blood plasma (author's transl)].

Authors:  H Hinghofer-Szalkay
Journal:  Klin Wochenschr       Date:  1980-10-15
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.