A comparison was made between the post-transfusion survival of red cells stored in standard ACD-A and in modified ACD-A, containing two-thirds the amount of citrate. Measurements of survival after 28 d storage in both solutions were made in each of six subjects. Mean post-transfusion survival with the two solutions was almost identical. When the results in one subject in whom survival was particularly bad with both solutions were omitted mean values at 24 h were 74.0% for standard ACD-A and 74.9% for modified ACD-A. It is concluded that viability is just as well maintained in modified ACD-A as in standard ACD-A. The results also provide further evidence of large differences between donors with respect to the maintenance of red cell viability during storage.Entities:
Mesh:
Substances:
Year: 1979 PMID: 508622 DOI: 10.1111/j.1365-2141.1979.tb03720.x
Source DB: PubMed Journal: Br J Haematol ISSN: 0007-1048 Impact factor: 6.998