Displacement of pacemaker leads--a 10-year survey.

G M Brewster, A L Evans.   

Abstract

Displacement of endocardial pacemaker leads from the initial site at the time of implantation is a major cause of unpredictable pacemaker failure. In this survey, we have made a retrospective study of the effectiveness of the attempts made by two manufacturers to design leads to reduce the frequency of this occurrence. The cumulative displacement records of 5 types of leads (Medtronic types 5818, 6904, 6901, and 6950, and Cardiac Pacemakers Inc. type 4210) have been studied, and show that Medtronic 5818 and 6950, and CPI 4210 leads are superior in this respect.

Entities:  

Mesh:

Year:  1979        PMID: 508447      PMCID: PMC482146          DOI: 10.1136/hrt.42.3.266

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  17 in total

1.  Permanent endocardial pacing. An analysis of 90 patients.

Authors:  T Havia; M Arstila; H Wendelin; R Heinonen
Journal:  Acta Med Scand Suppl       Date:  1976

2.  Complications with permanent endocardial electrode systems.

Authors:  O J Ohm; L Segadal; D W Skagen
Journal:  Acta Med Scand Suppl       Date:  1976

3.  Pacemaker wires and electrodes. A follow-up study.

Authors:  H Grendahl; E Sivertssen
Journal:  Acta Med Scand Suppl       Date:  1976

4.  Displacement of endocardial pacemaker electrodes. A comparison between Elema 588 B and Chardack 5818.

Authors:  J K Johansen; L H Andersen; A Kemp
Journal:  Acta Med Scand Suppl       Date:  1976

5.  Ventricular pacing with epigastric transdiaphragmatic electrodes. Long-term follow-up and comparison with other implantation methods.

Authors:  P J Buffle
Journal:  J Thorac Cardiovasc Surg       Date:  1976-08       Impact factor: 5.209

6.  Endocardial pacing electrode design and rate of displacement.

Authors:  R G Charles; L M Clarke; M Drysdale; R F Sequeira
Journal:  Br Heart J       Date:  1977-05

7.  [Complications of permanent cardiac stimulation. Personal experience].

Authors:  G Venere; L Barberis; G C Passerone; A Lijoi; A Brisighella
Journal:  Minerva Cardioangiol       Date:  1975-11       Impact factor: 1.347

8.  Patient survival and instrument performance with permanent cardiac pacing.

Authors:  L B McGuire; W M O'Brien; S P Nolan
Journal:  JAMA       Date:  1977-02-07       Impact factor: 56.272

9.  Complications of transvenous and transtboracic electrodes.

Authors:  S Kostiainen
Journal:  Acta Med Scand Suppl       Date:  1976

10.  Permanent pacemaker treatment at Gentofte hospital. A follow-up study with special reference to transvenous electrode complications, generator longevity and control procedures.

Authors:  J Berning; B Larsen
Journal:  Acta Med Scand Suppl       Date:  1976
View more
  2 in total

1.  Modern atrial and ventricular leads for permanent cardiac pacing.

Authors:  E J Perrins; R Sutton; B Kalebic; L R Richards; C Morley; B Terpstra
Journal:  Br Heart J       Date:  1981-08

2.  Predictive value of ST segment elevation in cardiac pacing.

Authors:  A G Arnold
Journal:  Br Heart J       Date:  1980-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.