The relation between videodensitometrically measured front velocity and electromagnetically assessed flow was examined in a circulatory model with continuous as well as pulsatile flow (89 experiments). The diameter of the tubes in the videodensitometric measuring section was 0.305 to 0.518 cm. A linear correlation was proved in flow velocities up to Reynold's number Re = 225. The exact flow, measured electromagnetically, was overestimated in continuous flow by 21% (r = 0.99, Syx = +/- 14.5 ml/min) and in pulsatile flow by 24% (r = 0.98, Syx = +/- 20.8 ml/min). In view of these results the phasic and average flow can be calculated accurately using videodensitometric techniques.Entities: