A comparison of descending arotic and "arterialized" capillary blood in the sick newborn.

J F Glasgow, D M Flynn, P R Swyer.   

Abstract

Comparison was made of 53 "arterialized" capillary (heel prick) samples with descending aortic blood in 26 babies, of whom 24 were less than one week old and 18 had R.D.S."Arterialized" capillary blood is an accurate and practical means of assessing aortic blood pH and Pco(2) over a range of 6.69 to 7.54 and 18 to 94 mm. Hg respectively."Arterialized" capillary sampling is a reliable means of assessing descending aortic Po(2) when the "arterialized" capillary value is less than 60 mm. Hg.When higher than 60 mm. Hg the "arterialized" capillary oxygen tension may be considerably less than that of the blood in the descending aorta, hence the "arterialized" capillary blood oxygen tension method is unreliable in estimating systemic oxygenation when the descending aortic oxygen tension is more than 60 mm. Hg.

Entities:  

Mesh:

Substances:

Year:  1972        PMID: 5062428      PMCID: PMC1940510     

Source DB:  PubMed          Journal:  Can Med Assoc J        ISSN: 0008-4409            Impact factor:   8.262


  12 in total

1.  THE VALIDITY OF PH AND PCO2 MEASUREMENTS IN CAPILLARY SAMPLES IN SICK AND HEALTHY NEWBORN INFANTS.

Authors:  G GANDY; L GRANN; N CUNNINGHAM; K ADAMSONS; L S JAMES
Journal:  Pediatrics       Date:  1964-08       Impact factor: 7.124

2.  COMPLICATIONS OF ARTERIAL PUNCTURE.

Authors:  S RAY
Journal:  Br Med J       Date:  1964-09-19

3.  SMALL BLOOD-SAMPLES FROM EAR-LOBE PUNCTURE: A SUBSTITUTE FOR ARTERIAL PUNCTURE.

Authors:  J H LANGLANDS; W F WALLACE
Journal:  Lancet       Date:  1965-08-14       Impact factor: 79.321

4.  Oxygen therapy in the newborn.

Authors:  N R Roberton; J M Gupta; G W Dahlenburg; J P Tizard
Journal:  Lancet       Date:  1968-06-22       Impact factor: 79.321

5.  Arterialized capillary sampling using histamine iontophoresis.

Authors:  R A Winquist; S J Stamm
Journal:  J Pediatr       Date:  1970-03       Impact factor: 4.406

6.  Reliability of oxygen tension measurements on arterialized capillary blood in the newborn.

Authors:  K R Mountain; D G Campbell
Journal:  Arch Dis Child       Date:  1970-02       Impact factor: 3.791

7.  Oxygen tension measurements on digital blood in the newborn.

Authors:  A J Corbet; E D Burnard
Journal:  Pediatrics       Date:  1970-11       Impact factor: 7.124

8.  Alveolar to arterial oxygen tension difference and venous admixture in newly born infants with congenital diaphragmatic herniation through the foramen of Bochdalek.

Authors:  A I Murdock; J B Burrington; P R Swyer
Journal:  Biol Neonate       Date:  1971

9.  Limb blood flow in the normal and sick newborn. A plethysmographic study.

Authors:  L Kidd; H Levison; P Gemmel; A Aharon; P R Swyer
Journal:  Am J Dis Child       Date:  1966-11

10.  Use of capillary blood in measurement of arterial PO2.

Authors:  J MacIntyre; J N Norman; G Smith
Journal:  Br Med J       Date:  1968-09-14
View more
  7 in total

1.  Some problems associated with measurement of physiological blood gases.

Authors:  J Dowd; L C Jenkins
Journal:  Can Anaesth Soc J       Date:  1973-03

2.  Prophylactic antibiotics in chronic umbilical artery catheterization in respiratory distress syndrome.

Authors:  H Bard; G Albert; F Teasdale; B Doray; B Martineau
Journal:  Arch Dis Child       Date:  1973-08       Impact factor: 3.791

3.  "Arterialized" capillary blood.

Authors:  A K Garg
Journal:  Can Med Assoc J       Date:  1972-07-08       Impact factor: 8.262

4.  Comparison of capillary and arterial blood gas measurements in neonates.

Authors:  B I McLain; J Evans; P R Dear
Journal:  Arch Dis Child       Date:  1988-07       Impact factor: 3.791

5.  Oxygen therapy in the newborn infant. Fetus and Newborn Committee. Canadian Paediatric Society.

Authors: 
Journal:  Can Med Assoc J       Date:  1975-10-18       Impact factor: 8.262

6.  Comparison of blood gas values in arterial and venous blood.

Authors:  Chellam Kirubakaran; J Ebor Jacob Gnananayagam; E Kalaranjini Sundaravalli
Journal:  Indian J Pediatr       Date:  2003-10       Impact factor: 1.967

7.  Correlation and Interchangeability of Venous and Capillary Blood Gases in Non-Critically Ill Neonates.

Authors:  Ratna N G B Tan; Steffen C Pauws; Evelyne van Loon; Vivanne E H J Smits; Enrico Lopriore; Arjan B Te Pas
Journal:  Front Pediatr       Date:  2018-04-12       Impact factor: 3.418

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.