Literature DB >> 50343

Radioimmunoassay of human serum antibody specific for adenovirus type 5-purified fiber.

J V Scott, G R Dreesman, G Spira, J A Kasel.   

Abstract

A radioimmunoassay (RIA), utilizing a second antibody to separate immune complexes, was developed to provide a sensitive and specific measure of serum antibody to adenovirus type 5 (Ad 5) fiber. Purity of fiber antigen was ascertained by sodium dodecyl sulfate urea-polyacrylamide gel electrophoresis and isoelectric focusing in ampholyte pH gradients. After labeling with 125I to high specific activity, the iodinated fiber did not exhibit loss of antigenic reactivity and remained stable for 3 weeks when stored at minus 20 degrees C with supplemental protein. Rabbit anti-Ad 5 serum with a neutralization titer of 1:320 precipitated 50% of the labeled fiber at a serum dilution of 1:50,000 when tested by the RIA. In competition assays as little as 0.5 ng of unlabeled fiber per millimeter was sufficient to inhibit the 125I fiber-antibody reaction. Serum specimens from 20 volunteers, obtained before and after vaccination with purified Ad 5 fiber or hexon subunit vaccine, were tested by RIA, hemagglutination-inhibition (HI), and neutralization tests. A comparison of mean antibody titers of post-inoculation sera showed that the RIA was 300 and 1000 times more sensitive than the HI and neutralization tests, respectively. Moreover, 19 of the men who were negative by the standard serologic tests before vaccination were shown to have anti-fiber antibody, with a mean RIA titer of 1:1028. Specificity of the RIA was demonstrated by the lack of an increase in antibody to Ad 5 fiber among those individuals vaccinated with the hexon subunit. Thus, the development of a highly sensitive and reproducible RIA allows for the detection of antibody specific for the Ad 5 fiber in serum which contains antibodies to the different virion antigenic determinants associated with Ad 5.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 50343

Source DB:  PubMed          Journal:  J Immunol        ISSN: 0022-1767            Impact factor:   5.422


  2 in total

1.  Radioimmunoprecipitation assay for quantitation of serum antibody to the hemagglutinin of type A influenza virus.

Authors:  H R Six; J A Kasel
Journal:  J Clin Microbiol       Date:  1978-02       Impact factor: 5.948

2.  Cell cytotoxicity due to specific influenza antibody production in vitro after recent influenza antigen stimulation.

Authors:  S B Greenberg; H R Six; S Drake; R B Couch
Journal:  Proc Natl Acad Sci U S A       Date:  1979-09       Impact factor: 11.205

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.