Literature DB >> 499236

An evaluation of six kits of technetium 99m human serum albumin injection for cardiac blood pool imaging.

A M Millar, W J Hannan, R P Sapru, A L Muir.   

Abstract

We have investigated the suitability of five different commercially available kits which provide human serum albumin (HSA) labelled with technetium 99m (99mTc) for cardiac blood pool imaging. Four of these products were one-step processes using stannous chloride as the reducing agent; the fifth was based on an electrolytic reduction. In addition, we also assessed our own modification of the electrolytic method. We measured the radiochemical purity by precipitation with trichloroacetic acid and by gel filtration on a Biogel P4 column. In addition, we measured the clearance of radioactivity from the blood at frequent time intervals after intravenous injection. Each product was assessed in separate groups of six patients. The labelling efficiency of the one-step kits varied between 73 and 93% compared with 94 and 98% for the electrolytically labelled albumin. The blood clearance for all one-step kits was significantly faster than that obtained for the radiopharmaceuticals prepared by the electrolytic method. We conclude that HSA labelled with 99mTc by the electrolytic method is to be preferred.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 499236     DOI: 10.1007/bf00626077

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  13 in total

1.  The assessment of left ventricular ejection fraction in patients with ischaemic heart disease by contrast ventriculography and nuclear angiography.

Authors:  A L Muir; W J Hannan; H M Brash; V Baldwa; H C Miller; B Ogilvie
Journal:  Clin Sci Mol Med       Date:  1977-07

2.  The effect of carrier technetium in the preparation of 99mTc-human serum albumin.

Authors:  W C Porter; H J Dworkin; R F Gutkowski
Journal:  J Nucl Med       Date:  1976-08       Impact factor: 10.057

3.  A rapid index of free activity in preparations of 99mTc-albumin.

Authors:  M Lamson; R J Callahan; F P Castronovo; K A McKusick; M S Potsaid
Journal:  J Nucl Med       Date:  1974-11       Impact factor: 10.057

4.  Noninvasive nuclear kinecardiography.

Authors:  N M Alpert; K A McKusick; G M Pohost; R E Dinsmore; M S Potsaid
Journal:  J Nucl Med       Date:  1974-12       Impact factor: 10.057

5.  Chromatographic quality control of 99mTc-labeled compounds.

Authors:  M W Billinghurst
Journal:  J Nucl Med       Date:  1973-11       Impact factor: 10.057

6.  Measurement of left ventricular ejection fraction.

Authors:  R H Secker-Walker; L Resnick; H Kunz; J A Parker; R L Hill; E J Potchen
Journal:  J Nucl Med       Date:  1973-11       Impact factor: 10.057

7.  99m Tc-human serum albumin.

Authors:  W C Eckelman; G Meinken; P Richards
Journal:  J Nucl Med       Date:  1971-11       Impact factor: 10.057

8.  A scintiphotographic method for measuring left ventricular ejection fraction in man without cardiac catheterization.

Authors:  H W Strauss; B L Zaret; P J Hurley; T K Natarajan; B Pitt
Journal:  Am J Cardiol       Date:  1971-11       Impact factor: 2.778

9.  A rapid and efficient method of preparing 99mTc-human serum albumin: its clinical applications.

Authors:  P P Benjamin
Journal:  Int J Appl Radiat Isot       Date:  1969-03

10.  Technetium-99m-human serum albumin: evaluation of a commercially produced kit.

Authors:  R J Callahan; K A McKusick; M Lamson; F P Castronovo; M S Potsaid
Journal:  J Nucl Med       Date:  1976-01       Impact factor: 10.057

View more
  8 in total

1.  Technetium-99m labelled human serum albumin for ventriculography: a comparative evaluation of six labelling kits.

Authors:  H P Vanbilloen; K A Verbeke; M J De Roo; A M Verbruggen
Journal:  Eur J Nucl Med       Date:  1993-06

2.  A radionuclide method for the simultaneous study of the effects of drugs on central and peripheral haemodynamics.

Authors:  C G Wathen; W J Hannan; C J Adie; A L Muir
Journal:  Br J Clin Pharmacol       Date:  1983-07       Impact factor: 4.335

3.  Radionuclide determined pulmonary blood volume in ischaemic heart disease.

Authors:  W J Hannan; J Vojacek; H M Connell; N G Dewhurst; A L Muir
Journal:  Thorax       Date:  1981-12       Impact factor: 9.139

4.  The effects of intravenous prenalterol on ventricular performance, as assessed by radionuclide ventriculography, in patients with ischaemic heart disease.

Authors:  A L Muir; W J Hannan; N G Dewhurst; I M Slessor
Journal:  Br J Clin Pharmacol       Date:  1981-10       Impact factor: 4.335

5.  Can right ventricular performance be assessed by equilibrium radionuclide ventriculography?

Authors:  Q F Xue; W MacNee; D C Flenley; W J Hannan; C J Adie; A L Muir
Journal:  Thorax       Date:  1983-07       Impact factor: 9.139

6.  Left ventricular function in hypothyroidism. Responses to exercise and beta adrenoceptor blockade.

Authors:  J C Forfar; A L Muir; A D Toft
Journal:  Br Heart J       Date:  1982-09

7.  Effects of felodipine on resistance and capacitance vessels in patients with essential hypertension.

Authors:  A L Muir; C G Wathen; W J Hannan
Journal:  Drugs       Date:  1985       Impact factor: 9.546

8.  The effect of the acute administration of tolbutamide on left ventricular function in insulin-dependent diabetics.

Authors:  A D Harrower; R D Adam; G McFarlane; R Railton; K C Young
Journal:  Acta Diabetol Lat       Date:  1981 Oct-Dec
  8 in total