| Literature DB >> 4991924 |
K Tsuji, E M Stapert, J H Robertson, P M Waiyaki.
Abstract
A sensitive sterility testing procedure for the detection of microbial contamination in petrolatum-based ointments is described. The method involves dissolving the ointment in filter-sterilized isopropyl myristate and filtering through a membrane filter. Improved sensitivity is obtained by blending the membrane in Trypticase Soy Broth before incubation. Filter-sterilized isopropyl myristate is shown to be less toxic to microorganisms than heat-sterilized isopropyl myristate. The isopropyl myristate method is more sensitive than the polyethylene glycol-ether method for the detection of microbial contamination.Entities:
Mesh:
Substances:
Year: 1970 PMID: 4991924 PMCID: PMC377050 DOI: 10.1128/am.20.5.798-801.1970