| Literature DB >> 4991917 |
S L Taylor, L R Fina, J L Lambert.
Abstract
Strongly basic anion-exchange resins form stable, water-insoluble combinations with triiodide ions. The combinations have remarkable antibacterial properties: 3.0 x 10(5)Escherichia coli cells per ml were killed when passed through a 3.8-g column of commercially available resin treated with triiodide (volume 4 ml after treatment). In an attempt to deplete the resin-triiodide complex, 1.14 x 10(9)E. coli cells in 15 liters were passed through the column with no significant loss of effectiveness. The antibacterial capabilities of the resin-triiodide columns ranged from 10(6)Salmonella typhimurium per ml to 1.1 x 10(4)Streptococcus faecalis per ml. Staphylococcus aureus and Pseudomonas aeruginosa were also tested and killed at concentrations of 1.8 x 10(4) and 1.3 x 10(5) per ml, respectively. The cells were not filtered from the water. They emerged from the column in nonviable form. This was demonstrated by using (14)C-labeled bacteria. The irreversible nature of the antibacterial action was revealed when attempts to wash the damaged cells did not restore viability.Entities:
Mesh:
Substances:
Year: 1970 PMID: 4991917 PMCID: PMC377032 DOI: 10.1128/am.20.5.720-722.1970
Source DB: PubMed Journal: Appl Microbiol ISSN: 0003-6919