Literature DB >> 4972272

Some problems in the use of the Coulter counter for erythrocyte total counts and volume distribution.

H B Collier.   

Abstract

Normal erythrocytes were subject to swelling and some haemolysis when suspended in a NaCl-formaldehyde-Na(2)EDTA diluent of pH 4.9 for routine blood-cell counting in the Coulter counter. A phosphate-buffered saline of pH 7.4 was substituted and has proven satisfactory for total erythrocyte counts. Polyvinyltoluene latex was unsuitable for volume calibration of the counter, because of aggregation of the particles in saline. Ragweed pollen grains gave a calibration factor that agreed well with that for fresh erythrocytes. Recent batches of Dade's Erythro-Trol (a suspension of fixed erythrocytes) were satisfactory for both total counts and volume calibration.

Entities:  

Mesh:

Substances:

Year:  1968        PMID: 4972272      PMCID: PMC473725          DOI: 10.1136/jcp.21.2.179

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  6 in total

1.  ACCURACY CONTROL OF BLOOD CELL COUNTS WITH THE COULTER COUNTER.

Authors:  E L PRUDEN; M E WINSTEAD
Journal:  Am J Med Technol       Date:  1964 Jan-Feb

2.  Size distribution of erythrocytes.

Authors:  G BRECHER; E F JAKOBEK; M A SCHNEIDERMAN; G Z WILLIAMS; P J SCHMIDT
Journal:  Ann N Y Acad Sci       Date:  1962-06-29       Impact factor: 5.691

3.  Electronic blood-cell counting.

Authors:  T B MAGATH; J BERKSON
Journal:  Am J Clin Pathol       Date:  1960-09       Impact factor: 2.493

4.  Rapid electronic measurement of cell volume and distribution.

Authors:  A C PEACOCK; G Z WILLIAMS; H F MENGOLI
Journal:  J Natl Cancer Inst       Date:  1960-07       Impact factor: 13.506

5.  The pH-resistance of erythrocytes. I. An investigation into the cause of haemolysis.

Authors:  E J VAN KAMPEN; C A GRAAFLAND; J J HASSELMAN
Journal:  Clin Chim Acta       Date:  1957-04       Impact factor: 3.786

6.  Evaluation of electronic red blood cell counter.

Authors:  G BRECHER; M SCHNEIDERMAN; G Z WILLIAMS
Journal:  Am J Clin Pathol       Date:  1956-12       Impact factor: 2.493

  6 in total
  3 in total

1.  The influence of extraneous factors on Coulter S measurement of the mean corpuscular volume.

Authors:  M Young; A C Lawrence
Journal:  J Clin Pathol       Date:  1975-01       Impact factor: 3.411

2.  Electrical sizing of particles in suspensions. II. Experiments with rigid spheres.

Authors:  N B Grover; J Naaman; S Ben-Sasson; F Doljanski; E Nadav
Journal:  Biophys J       Date:  1969-11       Impact factor: 4.033

3.  Cardio-metabolic and immunological impacts of extra virgin olive oil consumption in overweight and obese older adults: a randomized controlled trial.

Authors:  Mitra Rozati; Junaidah Barnett; Dayong Wu; Garry Handelman; Edward Saltzman; Thomas Wilson; Lijun Li; Junpeng Wang; Ascensión Marcos; José M Ordovás; Yu-Chi Lee; Mohsen Meydani; Simin Nikbin Meydani
Journal:  Nutr Metab (Lond)       Date:  2015-08-07       Impact factor: 4.169

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.