Microbiological evaluation of a large-volume air incinerator.

M S Barbeito, L A Taylor, R W Seiders.   

Abstract

Two semiportable metal air incinerators, each with a capacity of 1,000 to 2,200 standard ft(3) of air per min, were constructed to sterilize infectious aerosols created for investigative work in a microbiological laboratory. Each unit has about the same air-handling capacity as a conventional air incinerator with a brick stack but costs only about one-third as much. The units are unique in that the burner housing and combustion chamber are air-tight and utilize a portion of the contaminated air stream to support combustion of fuel oil. Operation is continuous. Aerosols of liquid and dry suspensions of Bacillus subtilis var. niger spores and dry vegetative cells of Serratia marcescens were disseminated into the two incinerators to determine the conditions required for sterilization of contaminated air. With the latter organisms (concentration 2.03 x 10(7) cells/ft(3) of air), a temperature of 525 F (274 C), measured at the firebox in front of the heat exchanger, was sufficient for sterilization. To sterilize 1.74 x 10(7) and 1.74 x 10(9) wet spores of B. subtilis per ft(3), the required temperature ranged from 525 to 675 F (274 to 357 C) and 625 to 700 F (329 to 371 C), respectively. Air-sterilization temperature varied with each incinerator. This was because of innate differences of fabrication, different spore concentrations, and use of one or two burners With dry B. subtilis spores (1.86 x 10(8)/ft(3)), a temperature of 700 F was required for sterilization. With dry spores, no difference was noted in the sterilization temperature for the two incinerators.

Entities:  

Mesh:

Year:  1968        PMID: 4967758      PMCID: PMC547446          DOI: 10.1128/am.16.3.490-495.1968

Source DB:  PubMed          Journal:  Appl Microbiol        ISSN: 0003-6919


  5 in total

1.  LABORATORY SAFETY IN RESEARCH WITH INFECTIOUS AEROSOLS.

Authors:  A G WEDUM
Journal:  Public Health Rep       Date:  1964-07       Impact factor: 2.792

2.  An electric incinerator for sterilization of small volumes of air.

Authors:  G G GREMILLION; L F MILLER; G A BODMER
Journal:  Appl Microbiol       Date:  1958-07

3.  Modifications of the high-speed safety blendor.

Authors:  M REITMAN; M A FRANK; R ALG; W S MILLER
Journal:  Appl Microbiol       Date:  1954-05

4.  Time temperature studies of spore penetration through an electric air sterilizer.

Authors:  H M DECKER; F J CITEK; J B HARSTAD; N H GROSS; F J PIPER
Journal:  Appl Microbiol       Date:  1954-01

5.  Emergency disinfection of operating room and patient ward with beta-propiolactone.

Authors:  M S Barbeito
Journal:  Hospitals       Date:  1966-03-16
  5 in total
  2 in total

1.  Microbiological hazard from the exhaust of a high-vacuum sterilizer.

Authors:  M S Barbeito; E A Brookey
Journal:  Appl Environ Microbiol       Date:  1976-11       Impact factor: 4.792

2.  New studies on the heat resistance of hamster-adapted scrapie agent: threshold survival after ashing at 600 degrees C suggests an inorganic template of replication.

Authors:  P Brown; E H Rau; B K Johnson; A E Bacote; C J Gibbs; D C Gajdusek
Journal:  Proc Natl Acad Sci U S A       Date:  2000-03-28       Impact factor: 11.205

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.