Literature DB >> 4956139

Effect of ethylene-diamine-tetra-acetic acid (dipotassium salt) and heparin on the estimation of packed cell volume.

C A Pennock, K W Jones.   

Abstract

The effect of varying concentrations of ethylene-diamine-tetra-acetic acid (E.D.T.A.) (dipotassium salt) and heparin on the estimation of packed cell volume has been studied using a microhaematocrit method. Varying concentrations of E.D.T.A. can produce serious errors in estimation of packed cell volume (P.C.V.) and reliable results are only obtained within the range of 1 to 2 mg./ml. Heparin is a more suitable anticoagulant for this investigation as varying the concentration has little effect. Storage with either anticoagulant at suitable concentrations for 24 hours at room temperature has little influence on the results.

Entities:  

Mesh:

Substances:

Year:  1966        PMID: 4956139      PMCID: PMC473232          DOI: 10.1136/jcp.19.2.196

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  9 in total

1.  ERROR IN HEMATOCRIT VALUE PRODUCED BY EXCESSIVE ETHYLENEDIAMINETETRAACETATE.

Authors:  J A LAMPASSO
Journal:  Am J Clin Pathol       Date:  1965-07       Impact factor: 2.493

2.  The amount of trapped plasma in a high speed micro-capillary hematocrit centrifuge.

Authors:  L GARBY; J C VUILLE
Journal:  Scand J Clin Lab Invest       Date:  1961       Impact factor: 1.713

3.  Determination of packed cell volume by centrifugation.

Authors:  R F JONES
Journal:  J Clin Pathol       Date:  1961-03       Impact factor: 3.411

4.  Correction for plasma trapped in the red cell column of the hematocrit.

Authors:  H CHAPLIN; P L MOLLISON
Journal:  Blood       Date:  1952-12       Impact factor: 22.113

5.  A microtechnique for measuring the haematocrit value.

Authors:  I KALDOR
Journal:  Med J Aust       Date:  1953-04-04       Impact factor: 7.738

6.  Use of sequestrene as an anticoagulant.

Authors:  G G HADLEY; N L LARSON
Journal:  Am J Clin Pathol       Date:  1953-06       Impact factor: 2.493

7.  The Errors of Some Haematological Methods as They Are Used in a Routine Laboratory.

Authors:  R Biggs; R L Macmillan
Journal:  J Clin Pathol       Date:  1948-11       Impact factor: 3.411

8.  An improved micro hematocrit method.

Authors:  M M STRUMIA; A B SAMPLE; E D HART
Journal:  Am J Clin Pathol       Date:  1954-09       Impact factor: 2.493

9.  The plasma in the packed cell column of the haematocrit.

Authors:  D LEESON; E B REEVE
Journal:  J Physiol       Date:  1951-10-29       Impact factor: 5.182

  9 in total
  1 in total

1.  Comparison of four different hematocrit assays and the effect of albumin on their measurements.

Authors:  Amelie Pare; Laura Kippen; Catherine Wagg; Matt Longmore; Soren Boysen
Journal:  Front Vet Sci       Date:  2022-08-24
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.