Detection of carotid occlusive disease by ultrasonic imaging and pulsed Doppler spectrum analysis.

W M Blackshear, D J Phillips, B L Thiele, J H Hirsch, P M Chikos, M R Marinelli, K J Ward, D E Strandness.   

Abstract

Ultrasonic imaging of the cervical carotid arteries by ultrasonic arteriography and duplex scanning combined with pulsed Doppler spectrum analysis were investigated in a series of patients undergoing arteriography. By using the ultrasonic image as a guide for precise placement of the pulsed Doppler sample volume, the characteristics of blood flow at points of interest in the carotid arteries could be determined. Audible analysis of the Doppler signal permitted correct diagnosis of 23 of 26 (88%) high-grade stenoses or occlusions with ultrasonic arteriography and 24 of 26 (92%) with duplex scanning. Spectrum analysis of Doppler signals obtained with the duplex scanner detected all of the 22 high-grade stenoses. Spectral abnormalities of a lesser degree also were detected in 18 of 23 vessels (78%) with atherosclerotic plaques which should not have reduced cerebral blood flow. These techniques permit the accurate detection of and the distinction between high-grade stenoses and occlusion, as well as the identification of many plaques which are not large enough to affect intracranial hemodynamics.

Entities:  

Mesh:

Year:  1979        PMID: 494062

Source DB:  PubMed          Journal:  Surgery        ISSN: 0039-6060            Impact factor:   3.982


  19 in total

1.  Clinical carotid measurements: present and future state.

Authors:  D E Strandness
Journal:  Tex Heart Inst J       Date:  1982-06

2.  In vivo recording of blood velocity profiles and studies in vitro of profile alterations induced by known stenoses.

Authors:  M Bassini; E Gatti; T Longo; G Martinis; P Pignoli; P L Pizzolati
Journal:  Tex Heart Inst J       Date:  1982-06

3.  Value of the spectral broadening index in continuous wave Doppler measurements.

Authors:  P F Wijn; P van der Sar; T H Gootzen; M H Tilmans; S H Skotnicki
Journal:  Med Biol Eng Comput       Date:  1987-07       Impact factor: 2.602

4.  Detection of low-grade arterial stenosis using an automatic minimum-flow-velocity tracking system (MVTS) as an adjunct to pulsed ultrasonic Doppler vessel imaging.

Authors:  S J Calil; V C Roberts
Journal:  Med Biol Eng Comput       Date:  1985-07       Impact factor: 2.602

5.  Duplex carotid ultrasound.

Authors:  J D Acker; C A Cole; K A Mauney; D M Joly; J E Machin
Journal:  Neuroradiology       Date:  1986       Impact factor: 2.804

6.  Hemispheric TIA and amaurosis fugax: what is their relation to stenotic lesions of internal carotid artery?

Authors:  A Visonà; L Lusiani; V Castellani; G Ronsisvalle; A Bonanome; P Nicolin; A Ventura; A Pagnan
Journal:  Heart Vessels       Date:  1987       Impact factor: 2.037

7.  Can clinical evaluation and noninvasive testing substitute for arteriography in the evaluation of carotid artery disease?

Authors:  W S Moore; S Ziomek; W J Quiñones-Baldrich; H I Machleder; R W Busuttil; J D Baker
Journal:  Ann Surg       Date:  1988-07       Impact factor: 12.969

8.  Continuous-wave versus range-gated pulsed Doppler power frequency spectrum analysis in the detection of carotid arterial occlusive disease.

Authors:  T R Harward; E F Bernstein; A Fronek
Journal:  Ann Surg       Date:  1986-07       Impact factor: 12.969

Review 9.  Noninvasive blood flow tests in vascular disease.

Authors:  O K Steinmetz; C W Cole
Journal:  Can Fam Physician       Date:  1993-11       Impact factor: 3.275

10.  Correlation of hemodynamically significant internal carotid stenosis with pulsed Doppler frequency analysis.

Authors:  W M Blackshear; S L Lamb; V S Kollipara; J D Anderson; F R Murtagh; C P Shah; M S Farber
Journal:  Ann Surg       Date:  1984-04       Impact factor: 12.969

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.