Literature DB >> 4825611

Experimental interactions of components of hemodialysis units with human blood.

W H Zucker, B A Shinoda, R G Mason.   

Abstract

An in vitro model test system for estimation of the blood compatibility of hemodialysis membranes and tubing is described. The model test system consists of a modified hemodialysis unit and blood pump through which fresh citrated human blood is circulated. The effects of the use of different pump and tubing types upon hematologic and blood coagulation parameters are described. Preexposure of test surfaces to albumin appeared to enhance blood compatibility characteristics of the model test system, whereas preexposure to a high density lipoprotein preparation or a proteinpolysaccharide preparation was without appreciable benefit. Use of blood from subjects receiving aspirin resulted in enhanced blood compatibility in the test system as did use of heparin. Use of Warfarin or dextran did not appear to enhance blood compatibility of test surfaces under the conditions of this test system. Dialysis membranes and tubing which formed parts of the test system were examined by scanning and transmission electron microscopy in control tests and in tests for effects of proteins and antithrombotic agents.

Entities:  

Mesh:

Substances:

Year:  1974        PMID: 4825611      PMCID: PMC1910818     

Source DB:  PubMed          Journal:  Am J Pathol        ISSN: 0002-9440            Impact factor:   4.307


  27 in total

Review 1.  Factors influencing platelet function: adhesion, release, and aggregation.

Authors:  J F Mustard; M A Packham
Journal:  Pharmacol Rev       Date:  1970-06       Impact factor: 25.468

2.  A comparison of proteinpolysaccharides of bovine nasal cartilage isolated and fractionated by different methods.

Authors:  L Rosenberg; S Pal; R Beale; M Schubert
Journal:  J Biol Chem       Date:  1970-08-25       Impact factor: 5.157

3.  Measurement of fibrinogen and fibrin degradation products in serum by staphylococcal clumping test.

Authors:  J Hawiger; S Niewiarowski; V Gurewich; D P Thomas
Journal:  J Lab Clin Med       Date:  1970-01

4.  Detection of intravascular coagulation by a serial-dilution protamine sulfate test.

Authors:  V Gurewich; E Hutchinson
Journal:  Ann Intern Med       Date:  1971-12       Impact factor: 25.391

5.  Electrophoresis of pig serum lipoproteins in agarose gel.

Authors:  M Kalab; W G Martin
Journal:  Anal Biochem       Date:  1968-08       Impact factor: 3.365

6.  Aggregation of human platelets by dextrans.

Authors:  D P Dhall; D R Harper; F N McKenzie; N A Matheson
Journal:  Nature       Date:  1966-05-14       Impact factor: 49.962

7.  Ethanol gelation: a rapid screening test for intravascular coagulation.

Authors:  F A Breen; J L Tullis
Journal:  Ann Intern Med       Date:  1968-12       Impact factor: 25.391

8.  Chronic hemodialysis with the hollow fiber artificial kidney (HFAK).

Authors:  F Gotch; B Lipps; J Weaver; J Brandes; J Rosin; J Sargent; P Oja
Journal:  Trans Am Soc Artif Intern Organs       Date:  1969

9.  Improving the accuracy of a rapid technique of plasma hemoglobin measurement.

Authors:  G L Hody; J A Breeden
Journal:  Am J Med Technol       Date:  1965 Sep-Oct

10.  Biochemical and biophysical aspects of human platelet adhesion to collagen fibers.

Authors:  B Lyman; L Rosenberg; S Karpatkin
Journal:  J Clin Invest       Date:  1971-09       Impact factor: 14.808

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.