Differential diagnosis of jaundice by 99mTc-IDA hepatobiliary imaging.

C Fonseca, L Rosenthall, D Greenberg, M Hernandez, A Arzoumanian.   

Abstract

The utility of 99mTc-IDA imaging in the differential diagnosis of jaundice was assessed. Although overall accuracy was 84%, this method is still inferior to the reported efficiency of ultrasonography and CT in making the correct diagnosis. Radionuclide imaging is a good alternative when these other modalities are not available and it functions well in an adjuvant capacity. The diagnostic limitations of 99mTc-dimethyl IDA imaging in cases of moderate to severe jaundice are largely overcome by the use of 99mTc-p-butyl IDA.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 477141     DOI: 10.1097/00003072-197904000-00001

Source DB:  PubMed          Journal:  Clin Nucl Med        ISSN: 0363-9762            Impact factor:   7.794


  2 in total

1.  Utility and accuracy of ultrasonically measured gallbladder wall as a diagnostic criteria in biliary tract disease.

Authors:  E A Deitch
Journal:  Dig Dis Sci       Date:  1981-08       Impact factor: 3.199

2.  The influence of bilirubin, alcohol and certain drugs on the kinetics of 99mTc-Diethyl IDA (EHIDA) in humans.

Authors:  J M Coenegracht; T L Oei; P J van Breda Vriesman
Journal:  Eur J Nucl Med       Date:  1983