Literature DB >> 475276

PTFE (Goretex) femoropopliteal reconstruction for limb salvage.

C A Clyne, J A McVeigh, M J Fox, G H Jantet, C W Jamieson.   

Abstract

We present the results of the use of polytetrafluoroethylene (PTFE, Goretex) grafts for limb salvage in 20 cases of femoropopliteal or more distal arterial reconstruction. There appears to be no relationship between graft survival and 'run-off' or the overall disease state of the vessels. Cumulative graft patency was almost 50% at 6 months, which is in contrast with higher patency rates reported from other countries.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 475276      PMCID: PMC2492184     

Source DB:  PubMed          Journal:  Ann R Coll Surg Engl        ISSN: 0035-8843            Impact factor:   1.891


  11 in total

1.  Prevention of platelet aggregation and adherence to prosthetic vascular grafts by aspirin and dipyridamole.

Authors:  R W Oblath; F O Buckley; R M Green; S I Schwartz; J A DeWeese
Journal:  Surgery       Date:  1978-07       Impact factor: 3.982

Review 2.  Amputation for vascular disease.

Authors:  C W Jamieson; D Hill
Journal:  Br J Surg       Date:  1976-09       Impact factor: 6.939

3.  Nonvein bypass in below-knee reoperation for lower limb ischemia.

Authors:  S J Burnham; D P Flanigan; J J Goodreau; J S Yao; J J Bergan
Journal:  Surgery       Date:  1978-09       Impact factor: 3.982

4.  Small vessel replacement with gore-tex (expanded polytetrafluoroethylene).

Authors:  A Florian; L H Cohn; G J Dammin; J J Collins
Journal:  Arch Surg       Date:  1976-03

5.  A small arterial substitute: expanded microporous polytetrafluoroethylene: patency versus porosity.

Authors:  C D Campbell; D Goldfarb; R Roe
Journal:  Ann Surg       Date:  1975-08       Impact factor: 12.969

6.  The use of expanded microporous polytetrafluoroethylene for limb salvage: a preliminary report.

Authors:  C D Campbell; D H Brooks; M W Webster; H T Bahnson
Journal:  Surgery       Date:  1976-05       Impact factor: 3.982

7.  Surgical treatment of the severely ischaemic leg: I. Survival rates.

Authors:  K A Myers; R B King; D F Scott; N Johnson; P J Morris
Journal:  Br J Surg       Date:  1978-07       Impact factor: 6.939

8.  Expanded polytetrafluoroethylene as a small artery replacement. A preliminary report.

Authors:  J M Johnson; D Goldfarb; L D Baker
Journal:  Am J Surg       Date:  1976-12       Impact factor: 2.565

9.  Evaluation of the thrombogenic potential of three types of arterial graft studied in an artificial circulation.

Authors:  G W Hamlin; S M Rajah; M J Crow; R C Kester
Journal:  Br J Surg       Date:  1978-04       Impact factor: 6.939

10.  The effect of smoking on the late patency of arterial reconstructions in the legs.

Authors:  K A Myers; R B King; D F Scott; N Johnson; P J Morris
Journal:  Br J Surg       Date:  1978-04       Impact factor: 6.939

View more
  3 in total

1.  Five year experience using PTFE vascular grafts for lower limb ischaemia.

Authors:  C A Clyne; C W Jamieson
Journal:  Ann R Coll Surg Engl       Date:  1985-09       Impact factor: 1.891

2.  Haemodynamic aspects of lower limb arterial reconstruction using Dacron and Goretex prostheses.

Authors:  E J Santiago; K Chatamra; D E Taylor
Journal:  Ann R Coll Surg Engl       Date:  1981-07       Impact factor: 1.891

3.  Dazoxiben examined for platelet inhibitory effect in an artificial circulation.

Authors:  M Goldman; C Hall; R J Hawker; C N McCollum
Journal:  Br J Clin Pharmacol       Date:  1983       Impact factor: 4.335

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.