Literature DB >> 4752413

The interrelationships and stability of Coulter S-determined blood indices.

P J Hamilton, R L Davidson.   

Abstract

The blood of 104 medical inpatients was examined at various intervals during storage for 72 hours using a Coulter S counter. Over this period remarkable stability of the white cell count, red cell count, haemoglobin, and mean cell haemoglobin was demonstrated. This permits a useful interpretation of indices obtained in routine postal samples sent to the laboratory by general practitioners for screening. Furthermore, the implications of high correlations between red cell indices in freshly examined blood are considered and the regression line MCV = 2.5 MCH + 16 is derived. Using this relationship the normal range of the Coulter S MCHC is defined as 32.6-33.7 g/dl. The significance of the Coulter MCHC in present-day practice is reassessed and the importance of recognizing values for MCV and MCH not coinciding with the regression line is briefly discussed.

Entities:  

Mesh:

Year:  1973        PMID: 4752413      PMCID: PMC477855          DOI: 10.1136/jcp.26.9.700

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  8 in total

1.  Determination of number and size of particles by electrical gating: blood cells.

Authors:  C F MATTERN; F S BRACKETT; B J OLSON
Journal:  J Appl Physiol       Date:  1957-01       Impact factor: 3.531

2.  Re-assessment of the reliability of the haematocrit.

Authors:  J M England; D M Walford; D A Waters
Journal:  Br J Haematol       Date:  1972-08       Impact factor: 6.998

3.  Red cell size as measured by the Coulter model S.

Authors:  T Okuno
Journal:  J Clin Pathol       Date:  1972-07       Impact factor: 3.411

Review 4.  Instrumentation and automation in clinical hematology.

Authors:  G M Brittin; G Brecher
Journal:  Prog Hematol       Date:  1971

5.  Epitaph for the M.C.H.C.

Authors:  P J Black
Journal:  Br Med J       Date:  1971-11-20

6.  Epitaph for the M.C.H.C.

Authors:  M S Rose
Journal:  Br Med J       Date:  1971-10-16

7.  An assessment of the Coulter counter model S.

Authors:  P H Pinkerton; I Spence; J C Ogilvie; W A Ronald; P Marchant; P K Ray
Journal:  J Clin Pathol       Date:  1970-02       Impact factor: 3.411

8.  An evaluation of the Coulter model S.

Authors:  D F Barnard; A B Carter; P J Crosland-Taylor; J W Stewart
Journal:  J Clin Pathol Suppl Coll Pathol       Date:  1969
  8 in total
  5 in total

1.  Stable blood cell counts after one-week storage at room temperature.

Authors:  Y Hirase; H Makatsuka; T Kawai; S Horiguchi; M Ikeda
Journal:  Bull Environ Contam Toxicol       Date:  1992-10       Impact factor: 2.151

Review 2.  Stability of haematological parameters and its relevance on the athlete's biological passport model.

Authors:  Giovanni Lombardi; Patrizia Lanteri; Alessandra Colombini; Giuseppe Lippi; Giuseppe Banfi
Journal:  Sports Med       Date:  2011-12-01       Impact factor: 11.136

3.  Coulter blood count.

Authors:  I Chanarin; J Cairns; D Waters
Journal:  J Clin Pathol       Date:  1973-12       Impact factor: 3.411

4.  [Detection of reagent errors by internal quality control of the Coulter counter S].

Authors:  R Kuse; K Hausmann
Journal:  Blut       Date:  1976-04

5.  A new method of quality control for the Coulter Model S Counter.

Authors:  D R Prangnell; P H Johnson
Journal:  J Clin Pathol       Date:  1977-05       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.