Literature DB >> 471369

A comparison of different methods of instrumental delivery based on electronic measurements of compression and traction.

A S Moolgaoker, S O Ahamed, P R Payne.   

Abstract

Electronic measurements of compression, using a hydrostatic technique, were made during 44 normal deliveries and compared with the values obtained during 32 deliveries using Kielland's forceps, 21 using Neville Barnes' forceps, 48 using Moolgaoker's adjustable forceps, and 26 using Malmstrom's vacuum extractor. Electronic recordings of traction, using strain gauges, were made simultaneously during all the instrumental deliveries except those with Kielland's forceps. By exercising suitable controls over most of the multiple factors operating at the time of any delivery the authors were able to compare objectively the efficiency of the different methods of instrumental delivery. Smaller forces of compression and traction were exerted and better Apgar scores were recorded in infants delivered with the adjustable forceps than in infants delivered with the other instruments. The superiority of the adjustable forceps was most noticeable during midcavity deliveries of the malrotated head.

Entities:  

Mesh:

Year:  1979        PMID: 471369

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  4 in total

Review 1.  Forces Involved with Labor and Delivery-A Biomechanical Perspective.

Authors:  Michele J Grimm
Journal:  Ann Biomed Eng       Date:  2021-01-11       Impact factor: 3.934

2.  Decreased neonatal pain response after vaginal-operative delivery with Kiwi OmniCup versus metal ventouse.

Authors:  E A Huhn; E Visca; D R Vogt; S von Felten; E M Tinner Oehler; C Bührer; D Surbek; R Zimmermann; I Hoesli
Journal:  BMC Pregnancy Childbirth       Date:  2017-01-31       Impact factor: 3.007

3.  Predictive value of traction force measurement in vacuum extraction: Development of a multivariate prognostic model.

Authors:  Kristina Pettersson; Khurram Yousaf; Jonas Ranstam; Magnus Westgren; Gunilla Ajne
Journal:  PLoS One       Date:  2017-03-03       Impact factor: 3.240

4.  Perinatal outcome after vacuum assisted delivery with digital feedback on traction force; a randomised controlled study.

Authors:  Stefhanie Romero; Kristina Pettersson; Khurram Yousaf; Magnus Westgren; Gunilla Ajne
Journal:  BMC Pregnancy Childbirth       Date:  2021-02-26       Impact factor: 3.007

  4 in total