Literature DB >> 4685409

Macroaggregated albumin studies of the coronary circulation in the dog.

D R Richmond, T Yipintsoi, C M Coulam, J L Titus, J B Bassingthwaighte.   

Abstract

Entities:  

Mesh:

Substances:

Year:  1973        PMID: 4685409      PMCID: PMC3137429     

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


× No keyword cloud information.
  32 in total

1.  DIAGNOSIS OF MASSIVE PULMONARY EMBOLISM IN MAN BY RADIOISOTOPE SCANNING.

Authors:  H N WAGNER; D C SABISTON; J G MCAFEE; D TOW; H S STERN
Journal:  N Engl J Med       Date:  1964-08-20       Impact factor: 91.245

2.  Estimation of coronary blood flow by washout of diffusible indicators.

Authors:  J B Bassingthwaighte; T Strandell; D E Donald
Journal:  Circ Res       Date:  1968-08       Impact factor: 17.367

3.  Myocardial perfusion imaging with radioactive-labeled particles injected directly into the coronary circulation of patients with coronary artery disease.

Authors:  W L Ashburn; E Braunwald; A L Simon; K L Peterson; J H Gault
Journal:  Circulation       Date:  1971-11       Impact factor: 29.690

4.  Combined inferior vena cavography, iliac venography, and lung imaging with 99mTc albumin macroaggregates.

Authors:  L Rosenthall
Journal:  Radiology       Date:  1971-03       Impact factor: 11.105

5.  Perfusion studies with technetium-99m human albumin microspheres (HAM).

Authors:  J A Burdine; R E Sonnemaker; L A Ryder; H J Spjut
Journal:  Radiology       Date:  1970-04       Impact factor: 11.105

6.  Albumin macroaggregates and measurements of regional blood flow: validity and application of particle sizing by Coulter counter.

Authors:  D R Richmond; W N Tauxe; J B Bassingthwaighte
Journal:  J Lab Clin Med       Date:  1970-02

7.  wo severe reactions following a pulmonary scan in a patient with idiopathic pulmonary haemosiderosis.

Authors:  A J Bliek; J E Bachynski
Journal:  J Nucl Med       Date:  1971-02       Impact factor: 10.057

8.  A computer-controlled scintiscanning system and associated computer graphic techniques for study of regional distribution of blood flow.

Authors:  C M Coulam; W H Dunnette; E H Wood
Journal:  Comput Biomed Res       Date:  1970-06

9.  Visual assessment of regional myocardial perfusion utilizing radioactive xenon and scintillation photography.

Authors:  P J Cannon; J I Haft; P M Johnson
Journal:  Circulation       Date:  1969-09       Impact factor: 29.690

10.  Validity of measuring regional pulmonary arterial blood flow with macroaggregates of human serum albumin.

Authors:  D E Tow; H N Wagner; V Lopez-Majano; E M Smith; T Migita
Journal:  Am J Roentgenol Radium Ther Nucl Med       Date:  1966-03
View more
  5 in total

Review 1.  Blood flow distributions by microsphere deposition methods.

Authors:  F W Prinzen; J B Bassingthwaighte
Journal:  Cardiovasc Res       Date:  2000-01-01       Impact factor: 10.787

Review 2.  The mechanical and metabolic basis of myocardial blood flow heterogeneity.

Authors:  J B Bassingthwaighte; D A Beard; Z Li
Journal:  Basic Res Cardiol       Date:  2001-11       Impact factor: 17.165

3.  Autoradiographic assessment of blood flow heterogeneity in the hamster heart.

Authors:  D D Stapleton; T C Moffett; D G Baskin; J B Bassingthwaighte
Journal:  Microcirculation       Date:  1995-09       Impact factor: 2.628

4.  Fractal 15O-labeled water washout from the heart.

Authors:  J B Bassingthwaighte; D A Beard
Journal:  Circ Res       Date:  1995-12       Impact factor: 17.367

5.  Validity of microsphere depositions for regional myocardial flows.

Authors:  J B Bassingthwaighte; M A Malone; T C Moffett; R B King; S E Little; J M Link; K A Krohn
Journal:  Am J Physiol       Date:  1987-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.