Literature DB >> 464121

In vivo measurement of blood vessel wall thickness.

G J L'italien, I G Kidson, J Megerman, W M Abbott.   

Abstract

To understand the mechanical properties of arteries and vascular grafts, it is crucial that the wall thickness in these vessels be known. Unfortunately, all availble methods for measuring this parameter require the removal of the vessel, which precludes the study of such vessels as a function of time. A new radiographic technique for measuring the wall thickness of arteries and vascular grafts in vivo, utilizing contrast materials injected into the vessel lumen and applied to the outer surface of the vessel, is described. Radiographs are obtained with a portable X-ray machine and analyzed using a calibrated microscope. The technique has been successfully applied to the in vivo measurement of wall thickness in canine arteries, veins, and experimental vascular grafts. It is concluded that the method provides better than 95% accuracy in a variety of vessels and that it can be used to study changes in vascular grafts after their implantation into the arterial circulation.

Entities:  

Mesh:

Year:  1979        PMID: 464121     DOI: 10.1152/ajpheart.1979.237.2.H265

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  1 in total

1.  The effect of wall mechanical properties on patency of arterial grafts.

Authors:  I G Kidson
Journal:  Ann R Coll Surg Engl       Date:  1983-01       Impact factor: 1.891

  1 in total