Literature DB >> 464066

Determinations of blood flow and shunting of 9- and 15-micrometer spheres in regional beds.

F C Fan, G B Schuessler, R Y Chen, S Chien.   

Abstract

In 17 pentobarbitalized dogs, the shunting of 15-micrometer and 9-micrometer microspheres was studied in the brain, myocardium, kidney, intestine, and lung. The veins of these organs were catheterized for constant blood withdrawal for 2 min by direct venipuncture. The ratio of microsphere radioactivity in the venous blood to that in the arterial blood gave the shunting of microspheres by the venous sampling technique. The 15-micrometer microspheres showed 2% or less shunting for all organs studied, whereas the 9-micrometer microspheres had shunting ranging from 3% in the coronary sinus to 24% in the portal vein. The shunting of 9-micrometer microspheres was also calculated from direct tissue counting, where the 15-micrometer spheres were considered to be completely entrapped. The results of direct tissue counting indicate that the 2-min venous sampling underestimates microsphere shunting. CO2 administration increased significantly the shunting of 9-micrometer spheres, whereas the shunting of 15-micrometer spheres determined by venous sampling remained less than 2%. Consideration of shunting indicates that the 15-micrometer microspheres might be more appropriate for regional organ blood flow measurements, including the myocardium.

Entities:  

Mesh:

Year:  1979        PMID: 464066     DOI: 10.1152/ajpheart.1979.237.1.H25

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  20 in total

1.  Regional cerebral blood flow in pigs estimated by microspheres.

Authors:  F F Madsen; F T Jensen; M Vaeth; J C Djurhuus
Journal:  Acta Neurochir (Wien)       Date:  1990       Impact factor: 2.216

2.  Tissue blood flow and localization of arteriovenous anastomoses in pigs with microspheres of four different sizes.

Authors:  P R Saxena; P D Verdouw
Journal:  Pflugers Arch       Date:  1985-02       Impact factor: 3.657

Review 3.  Proposed methods for the measurement of regional renal blood flow using heat transfer analysis.

Authors:  T Adams; W S Spielman; K R Holmes; S R Heisey; M M Chen
Journal:  Ann Biomed Eng       Date:  1985       Impact factor: 3.934

4.  Changes in blood flow, portal pressure and shunting during the development of cirrhosis in response to beta-blockade.

Authors:  M McLaren; S Braye; J Fleming; S Karran; I Taylor
Journal:  Gut       Date:  1987-06       Impact factor: 23.059

5.  The microcirculation during enflurane and isoflurane anaesthesia in dogs.

Authors:  H Yano; M Takaori
Journal:  Can J Anaesth       Date:  1994-02       Impact factor: 5.063

6.  A study of the vascular arrangement in the rat adrenal gland using non-radioactive microspheres.

Authors:  M Hamaji; M Miyata; Y Kawashima
Journal:  Cell Tissue Res       Date:  1985       Impact factor: 5.249

7.  Blood flow through arteriovenous anastomoses and its thermal function in the laying hen.

Authors:  D Wolfenson
Journal:  J Physiol       Date:  1983-01       Impact factor: 5.182

8.  Early shunting of 9 microns and 15 microns tracer microspheres from the acutely ischemic canine myocardium.

Authors:  W Meesmann; S von Krosigk; M Neumann; C Martin; H Hirche; T Horacek; R Sautter; M Budden
Journal:  Basic Res Cardiol       Date:  1983 May-Jun       Impact factor: 17.165

9.  Omental transposition or transplantation to the brain and superficial temporal artery--middle cerebral artery anastomosis in preventing experimental cerebral ischaemia.

Authors:  G B Azzena; G Campus; O Mameli; S Moraglia; G Padua; A Pau; S Pau; P Ruju; E Sehrbundt Viale; E Tolu; S Turtas; G L Viale
Journal:  Acta Neurochir (Wien)       Date:  1983       Impact factor: 2.216

10.  Redistribution by 5-hydroxytryptamine of carotid arterial blood at the expense of arteriovenous anastomotic blood flow.

Authors:  P R Saxena; P D Verdouw
Journal:  J Physiol       Date:  1982-11       Impact factor: 5.182

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.