A pulsed dye laser was used as an excitation source in a fluorescent treponemal antibody absorption (FTA-ABS) test. A high precision in quantitative fluorescence was obtained with this high-power excitation source coupled to an electronic detection system and a storage oscilloscope by standardization of fluorescence evaluation and through elimination of human error. One 0.4-mus pulse exposure was sufficient to record fluorescence intensity data on the oscilloscope. Absence of fading of fluorescence after repeated excitation permitted multiple readings of the same microscope field. Almost 100% reproducible results were obtained for the FTA-ABS test with 40 samples. Electronic detection of fluorescence and the high sensitivity obtained with laser excitation raise doubts about the relative value of quantitative immunofluorescence in the FTA-ABS test.

Entities:  

Mesh:

Substances:

Year:  1974        PMID: 4598221      PMCID: PMC380160          DOI: 10.1128/am.27.5.838-843.1974

Source DB:  PubMed          Journal:  Appl Microbiol        ISSN: 0003-6919


  8 in total

1.  The pulsed dye laser as a light source for the fluorescent antibody technique.

Authors:  N R Bergquist
Journal:  Scand J Immunol       Date:  1973       Impact factor: 3.487

2.  Automation of the fluorescent treponemal antibody-absorption test.

Authors:  G I Kaufman; J F Nester
Journal:  J Histochem Cytochem       Date:  1972-04       Impact factor: 2.479

3.  Further evaluation of an automated fluorescent treponemal antibody test for syphilis.

Authors:  A Birry; M Caloenescu; S S Kasatiya
Journal:  Am J Clin Pathol       Date:  1972-03       Impact factor: 2.493

4.  The use of incident light in immunofluorescence applied to syphilis serology.

Authors:  S S Kasatiya; A Birry
Journal:  Am J Clin Pathol       Date:  1972-03       Impact factor: 2.493

5.  The use of a vertical illuminator with interchangeable dichroic mirrors for fluorescence microscopy with incidental light.

Authors:  J S Ploem
Journal:  Z Wiss Mikrosk       Date:  1967-11

6.  Fluorescent treponemal antibody-absorption (FTA-ABS) test for syphilis.

Authors:  W E Deacon; J B Lucas; E V Price
Journal:  JAMA       Date:  1966-11-07       Impact factor: 56.272

7.  Quantitative fluorescence microscopy: fluorescent antibody automatic scanning techniques.

Authors:  H P Mansberg; J Kusnetz
Journal:  J Histochem Cytochem       Date:  1966-03       Impact factor: 2.479

8.  An experimental study of lasers as excitation sources for automated fluorescent antibody instrumentation.

Authors:  G I Kaufman; J F Nester; D E Wasserman
Journal:  J Histochem Cytochem       Date:  1971-08       Impact factor: 2.479

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.