| Literature DB >> 458615 |
Abstract
A fluorometric determination for chlorzoxazone was developed based on the intrinsic drug fluorescence in chloroform using excitation and emission wavelengths of 286 and 310 nm, respectively. A calibration curve for chlorzoxazone in chloroform gave a linear working range of 0.027-2.3 microgram/ml (r = 0.9999) with the minimum detectability at 27 ng/ml. The procedure was applied to chlorzoxazone analysis in spiked plasma and urine samples. Minimum detectable drug levels in these samples were 60 and 130 ng/ml, respectively. Data revealed that chlorzoxazone could be determined in plasma and urine even in the presence of 20-fold molar excesses of its major metabolite, 6-hydroxychlorzoxaxone, and acetaminophen. The method also was applicable to chlorzoxazone analysis in a commercial dosage form containing acetaminophen.Entities:
Mesh:
Substances:
Year: 1979 PMID: 458615 DOI: 10.1002/jps.2600680735
Source DB: PubMed Journal: J Pharm Sci ISSN: 0022-3549 Impact factor: 3.534