Literature DB >> 4553802

Semiautomated method for microbiological vitamin assays.

T M Berg, H A Behagel.   

Abstract

A semiautomated method for microbiological vitamin assays is described, which includes separate automated systems for the preparation of the cultures and for the measurement of turbidity. In the dilution and dosage unit based on the continuous-flow principle, vitamin samples were diluted to two different dose levels at a rate of 40 per hr, mixed with the inoculated test broth, and dispensed into culture tubes. After incubation, racks with culture tubes were placed on the sampler of an automatic turbidimeter. This unit, based on the discrete-sample system, measured the turbidity and printed the extinction values at a rate of 300 per hr. Calculations were computerized and the results, including statistical data, are presented in an easily readable form. The automated method is in routine use for the assays of thiamine, riboflavine, pyridoxine, cyanocobalamin, calcium pantothenate, nicotinic acid, pantothenol, and folic acid. Identical vitamin solutions assayed on different days gave variation coefficients for the various vitamin assays of less than 10%.

Entities:  

Mesh:

Substances:

Year:  1972        PMID: 4553802      PMCID: PMC380383          DOI: 10.1128/am.23.3.531-542.1972

Source DB:  PubMed          Journal:  Appl Microbiol        ISSN: 0003-6919


  8 in total

1.  Automated microbiological analyses for tetracycline and polyenes.

Authors:  T A HANEY; J R GERKE; M E MADIGAN; J F PAGANO
Journal:  Ann N Y Acad Sci       Date:  1962-08-20       Impact factor: 5.691

2.  Automation of the microbiological assay of antibiotics with an autoanalyzer instrumental system.

Authors:  J R GERKE; T A HANEY; J F PAGANO; A FERRARI
Journal:  Ann N Y Acad Sci       Date:  1960-07-22       Impact factor: 5.691

3.  An automated turbidimetric system for antibiotic assay.

Authors:  T B Platt; J Gentile; M J George
Journal:  Ann N Y Acad Sci       Date:  1965-11-09       Impact factor: 5.691

4.  A new automated system for microbiological assays.

Authors:  J R McMahan
Journal:  Ann N Y Acad Sci       Date:  1965-11-09       Impact factor: 5.691

5.  Automation in the microbiological assays of antibiotics.

Authors:  R Dewart; F Naudts; W Lhoest
Journal:  Ann N Y Acad Sci       Date:  1965-11-09       Impact factor: 5.691

6.  Automated system for analytical microbiology. II. Construction of system and evaluation of antibiotics and vitamins.

Authors:  N R Kuzel; F W Kavanagh
Journal:  J Pharm Sci       Date:  1971-05       Impact factor: 3.534

7.  Automated system for analytical microbiology. I. Theory and design considerations.

Authors:  N R Kuzel; F W Kavanagh
Journal:  J Pharm Sci       Date:  1971-05       Impact factor: 3.534

8.  Automated turbidimetric bioassay readout instrument using a multiple flow-cell system.

Authors:  K Tsuji; D A Griffith; C C Sperry
Journal:  Appl Microbiol       Date:  1967-01
  8 in total
  2 in total

1.  Semiautomated microbiological method for the assay of quaternary ammonium compounds.

Authors:  T M Berg
Journal:  Appl Microbiol       Date:  1975-06

2.  Semielectronic turbidimeter for automated monitoring of bacterial growth in test tubes.

Authors:  J H Marcelis; H Versteeg; H J Beck; D Vinke
Journal:  Appl Environ Microbiol       Date:  1980-02       Impact factor: 4.792

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.