Literature DB >> 4476198

Rubella hemagglutination inhibition: removal of nonspecific agglutination due to manganous chloride.

S A Biano, T W Chang, J B Daniels.   

Abstract

Nonspecific inhibitors of rubella hemagglutination can be removed by treatment of sera with heparin-manganous chloride for use in the hemagglutination-inhibition test. After removal of nonspecific inhibitors by this procedure, an excess of manganous chloride may remain. This may cause the cells to agglutinate, thus obscuring the reading at low serum dilutions. This disadvantage can be overcome by the addition of sodium carbonate, which forms an insoluble compound with manganous chloride and does not interfere with antibody determination. The procedure presents a further refinement of the hemagglutination inhibition test for rubella by increasing specificity and sensitivity; it permits detection of antibody levels as low as 1:4 in sera.

Entities:  

Mesh:

Substances:

Year:  1974        PMID: 4476198      PMCID: PMC186869          DOI: 10.1128/am.28.6.992-994.1974

Source DB:  PubMed          Journal:  Appl Microbiol        ISSN: 0003-6919


  4 in total

1.  [Precipitation of the beta-lipoproteins of serum by heparin in presence of certain bivalent cations].

Authors:  M BURSTEIN; A PRAVERMAN
Journal:  C R Hebd Seances Acad Sci       Date:  1957-12-23

2.  The nonspecific inhibitors of rubella-virus hemagglutination.

Authors:  H J Dold; R L Northrop
Journal:  Proc Soc Exp Biol Med       Date:  1968-06

3.  Rubella-virus hemagglutination-inhibition test.

Authors:  G L Stewart; P D Parkman; H E Hopps; R D Douglas; J P Hamilton; H M Meyer
Journal:  N Engl J Med       Date:  1967-03-09       Impact factor: 91.245

4.  RUBELLA ANTIBODIES IN HUMAN SERUM: DETECTION BY THE INDIRECT FLUORESCENT ANTIBODY TECHNIC.

Authors:  G C BROWN; H F MAASSAB; J A VERONELLI; T J FRANCIS
Journal:  Science       Date:  1964-08-28       Impact factor: 47.728

  4 in total
  3 in total

1.  Simple procedure for the removal of nonspecific inhibitors of rubella virus hemagglutination.

Authors:  R Allen; K Hedlund
Journal:  J Clin Microbiol       Date:  1975-12       Impact factor: 5.948

2.  An alternative method for inactivating heteroagglutinins in human sera applicable to rubella haemagglutination inhibition testing at low dilutions.

Authors:  P P Mortimer
Journal:  J Clin Pathol       Date:  1976-05       Impact factor: 3.411

3.  Rubella hemagglutination-inhibition test: false-positive reactions in sera contaminated with bacteria.

Authors:  J B Campbell; M Romach; M L Ellins
Journal:  J Clin Microbiol       Date:  1976-11       Impact factor: 5.948

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.