Literature DB >> 446130

Two-dimensional echocardiographic features of bicuspid aortic valve.

R E Fowles, R P Martin, J M Abrams, J N Schapira, J W French, R L Popp.   

Abstract

The two-dimensional cross-sectional echocardiographic diagnosis of bicuspid aortic valves is described and compared with results of M-mode echocardiograms. Aortic valve anatomy was determined in 19 selected patients by angiography, and confirmed in five by direct surgical visualization. Using an eccentricity index (EI) of 1.3 or greater as diagnostic of bicuspid aortic valve, M-mode correctly identified anatomy in 14 of 19 valves (74 percent), although EI varied in several patients. For two-dimensional diagnosis of bicuspid aortic valve, short axis cross section was preferred, and criteria included number of cusps seen in real time motion, irregularity of folding of cusp margins, and location of commissural insertions. Two-dimensional echocardiography correctly identified anatomy in 18 of 19 valves (95 percent). Long axis cross section disclosed valvular doming in all 8 patients in whom doming was observed angiographically, correlating with hemodynamic findings. Two-dimensional echocardiography aids in the detection of bicuspid aortic valve in a suspected population, can give an estimate of valve gradients, and explains variability in M-mode findings. As such, two-dimensional echocardiography is a valuable tool in the noninvasive diagnosis of the bicuspid aortic valve.

Entities:  

Mesh:

Year:  1979        PMID: 446130     DOI: 10.1378/chest.75.4.434

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  4 in total

1.  Two dimensional echocardiographic assessment of aortic valve morphology: feasibility of bicuspid valve detection. Prospective study of 100 adult patients.

Authors:  M J Zema; M Caccavano
Journal:  Br Heart J       Date:  1982-11

2.  Comparison of echocardiography and angiography in determining the cause of severe aortic regurgitation.

Authors:  N L DePace; P F Nestico; M N Kotler; G S Mintz; D Kimbiris; I P Goel; E E Glazier-Laskey; J Ross
Journal:  Br Heart J       Date:  1984-01

3.  Diagnostic accuracy study of routine echocardiography for bicuspid aortic valve: a retrospective study and meta-analysis.

Authors:  Mathias Hillebrand; Dietmar Koschyk; Pia Ter Hark; Helke Schüler; Meike Rybczynski; Jürgen Berger; Amit Gulati; Alexander M Bernhardt; Christian Detter; Evaldas Girdauskas; Stefan Blankenberg; Yskert von Kodolitsch
Journal:  Cardiovasc Diagn Ther       Date:  2017-08

4.  Ex vivo evidence for the contribution of hemodynamic shear stress abnormalities to the early pathogenesis of calcific bicuspid aortic valve disease.

Authors:  Ling Sun; Santanu Chandra; Philippe Sucosky
Journal:  PLoS One       Date:  2012-10-31       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.