Literature DB >> 4430128

Factors contributing to intra-individual variation of serum constituents: 4. Effects of posture and tourniquet application on variation of serum constituents in healthy subjects.

B E Statland, H Bokelund, P Winkel.   

Abstract

Mesh:

Substances:

Year:  1974        PMID: 4430128

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


× No keyword cloud information.
  10 in total

1.  Biochemistry on the human scale.

Authors:  Ken Sikaris
Journal:  Clin Biochem Rev       Date:  2010-11

2.  Time course of changes in concentration of some plasma components after frusemide.

Authors:  T O Haug
Journal:  Br Med J       Date:  1976-09-11

3.  Reference distributions for immunoglobulins A, G, and M: a practical, simple, and clinically relevant approach in a large cohort.

Authors:  R F Ritchie; G E Palomaki; L M Neveux; O Navolotskaia; T B Ledue; W Y Craig
Journal:  J Clin Lab Anal       Date:  1998       Impact factor: 2.352

Review 4.  Fundamental issues in clinical chemistry.

Authors:  B E Statland
Journal:  Am J Pathol       Date:  1979-04       Impact factor: 4.307

5.  Determining clinical significance in repeated laboratory measurements. The "Clinical Delta Range".

Authors:  D Lezotte; R R Grams
Journal:  J Med Syst       Date:  1979       Impact factor: 4.460

Review 6.  Harmonization of blood-based indicators of iron status: making the hard work matter.

Authors:  Andrew N Hoofnagle
Journal:  Am J Clin Nutr       Date:  2017-10-25       Impact factor: 7.045

7.  Physiological and analytical variation in cholesterol and triglycerides.

Authors:  G R Warnick; J J Albers
Journal:  Lipids       Date:  1976-03       Impact factor: 1.880

8.  Patient posture for blood collection by venipuncture: recall for standardization after 28 years.

Authors:  Gabriel Lima-Oliveira; Gian Cesare Guidi; Gian Luca Salvagno; Elisa Danese; Martina Montagnana; Giuseppe Lippi
Journal:  Rev Bras Hematol Hemoter       Date:  2017-02-22

Review 9.  Quality Assurance in Clinical Chemistry: A Touch of Statistics and A Lot of Common Sense.

Authors:  Elvar Theodorsson
Journal:  J Med Biochem       Date:  2016-05-09       Impact factor: 3.402

Review 10.  Blood Biomarker Profiling and Monitoring for High-Performance Physiology and Nutrition: Current Perspectives, Limitations and Recommendations.

Authors:  Charles R Pedlar; John Newell; Nathan A Lewis
Journal:  Sports Med       Date:  2019-12       Impact factor: 11.136

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.