Literature DB >> 4420188

Differential white cell counts by frequency distribution analysis of cell volumes.

N C Hughes-Jones, I Norley, J M Young, J M England.   

Abstract

Absolute neutrophil and lymphocyte counts on peripheral blood can be made by analysis of the output from a Coulter particle counter, utilizing the difference in the relative cell volume between these two types of cell. A comparison has been made between the results obtained by volume analysis and those obtained by standard microscopical techniques in 10 normal people and 45 patients. The absolute neutrophil count obtained by volume analysis agreed well with values obtained by microscopy; the lymphocyte count did not give such good agreement, since the smaller number of cells counted gave rise to larger sampling errors. The method of volume analysis is suitable for the assessment of absolute neutrophil counts for clinical use.

Entities:  

Mesh:

Substances:

Year:  1974        PMID: 4420188      PMCID: PMC475415          DOI: 10.1136/jcp.27.8.623

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  5 in total

1.  Isolation of leucocytes from human blood. Further observations. Methylcellulose, dextran, and ficoll as erythrocyteaggregating agents.

Authors:  A Böyum
Journal:  Scand J Clin Lab Invest Suppl       Date:  1968

2.  Rapid and reliable differential counts on dilute leukocyte suspensions.

Authors:  T E Oberjat; R M Zucker; B Cassen
Journal:  J Lab Clin Med       Date:  1970-09

3.  Volume analysis of human peripheral blood leukocytes.

Authors:  R K Humphries; R G Miller
Journal:  Ser Haematol       Date:  1972

4.  Volume distribution and separation of normal human leucocytes.

Authors:  M A Van Dilla; M J Fulwyler; I U Boone
Journal:  Proc Soc Exp Biol Med       Date:  1967-06

5.  Human leukocytes: their size distribution and mean corpuscular volume.

Authors:  J Gauthier; P Harel
Journal:  Can Med Assoc J       Date:  1967-09-23       Impact factor: 8.262

  5 in total
  5 in total

1.  Anisocytosis and the C-1000 Channelyzer in macrocytic anaemia.

Authors:  S J Proctor; J R Cox; T J Sheridan
Journal:  J Clin Pathol       Date:  1976-08       Impact factor: 3.411

2.  Abridged differential leucocyte counts provided by a Coulter Channelyzer in a routine haematology laboratory.

Authors:  P A Wycherley; M J O'shea
Journal:  J Clin Pathol       Date:  1978-03       Impact factor: 3.411

3.  Automated differential leucocyte counting: present status and future trends.

Authors:  S M Lewis
Journal:  Blut       Date:  1981-07

4.  Estimation of lymphocyte percentage and number on the Coulter Counter, Model S Plus Phase II.

Authors:  J M England; M C Chetty; P M De Silva
Journal:  J Clin Pathol       Date:  1982-11       Impact factor: 3.411

5.  Cell volumes of normal and malignant mononuclear cells.

Authors:  E H Chapman; A S Kurec; F R Davey
Journal:  J Clin Pathol       Date:  1981-10       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.