Specific gamma-ray constant and exposure rate constant of 192Ir.

G P Glasgow, L T Dillman.   

Abstract

Calculated values of the 192Ir specific gamma-ray constant, Gamma range from the low value of 3.948 R cm2h-1mCi-1 recommended in NCRP No. 41 to a high of 4.89 R cm2h-1mCi-1. Measured values of Gamma range only from 4.85 to 5.0 Rcm2h-1mCi-1. Discrepancies in reported calculated values exist because the isotope decay scheme and other nuclear spectroscopy data pertinent to these calculations were not well known. Using the 28 gamma rays and relative intensities from the most recent Evaluated Nuclear Structure Data File (ENSDF), Gamma is calculated to be 4.62 +/- 0.05 Rcm2h-1mCi-1 and the exposure rate constant Gamma delta is 4.69 +/- 0.05 Rcm2h-1mCi-1. These new calculations are presented and previously reported values of Gamma and Gamma delta are reviewed.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 440232     DOI: 10.1118/1.594551

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Ice as a water-equivalent solid medium for brachytherapy dosimetric measurements.

Authors:  Haijun Song; Zhe Chen; Ning Yue; Qingrong Wu; Fang-Fang Yin
Journal:  Radiat Environ Biophys       Date:  2008-12-09       Impact factor: 1.925

2.  Dose perturbation due to the polysulfone cap surrounding a Fletcher-Williamson colpostat.

Authors:  Michael J Price; Stephen F Kry; Patricia J Eifel; Mohammad Salehpour; Firas Mourtada
Journal:  J Appl Clin Med Phys       Date:  2010-01-28       Impact factor: 2.102

3.  Dosimetric assessment of an air-filled balloon applicator in HDR vaginal cuff brachytherapy using the Monte Carlo method.

Authors:  Hongyu Jiang; Rajeev Badkul; Damodar Pokhrel
Journal:  J Appl Clin Med Phys       Date:  2018-03-01       Impact factor: 2.102

4.  BrachyGuide: a brachytherapy-dedicated DICOM RT viewer and interface to Monte Carlo simulation software.

Authors:  Evaggelos Pantelis; Vassiliki Peppa; Vasileios Lahanas; Eleftherios Pappas; Panagiotis Papagiannis
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

5.  The effect of tandem-ovoid titanium applicator on points A, B, bladder, and rectum doses in gynecological brachytherapy using 192Ir.

Authors:  Mohammad Hosein Sadeghi; Sedigheh Sina; Amir Mehdizadeh; Reza Faghihi; Vahed Moharramzadeh; Ali Soleimani Meigooni
Journal:  J Contemp Brachytherapy       Date:  2018-02-28
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.