Literature DB >> 426402

Fatal pulmonary hemorrhage after use of the flow-directed balloon-tipped catheter.

L A Pape, C I Haffajee, J E Markis, I S Ockene, J A Paraskos, J E Dalen, J S Alpert.   

Abstract

The flow-directed balloon-tipped catheter is extensively used in intensive care units, catheterization laboratories, operating rooms, and emergency wards. Major complications associated with its use have not been frequently reported. In a recent 2-year period in four hospitals, we identified five cases of fatal pulmonary hemorrhage resulting from balloon-tipped catheters. We review here four additional cases previously cited in the literature and discuss possible mechanisms and predisposing factors associated with this complication and guidelines for safe use of these catheters. Pulmonary artery rupture is probably commoner than previously reported.

Entities:  

Mesh:

Year:  1979        PMID: 426402     DOI: 10.7326/0003-4819-90-3-344

Source DB:  PubMed          Journal:  Ann Intern Med        ISSN: 0003-4819            Impact factor:   25.391


  10 in total

1.  Catheter-induced pulmonary artery perforation associated with an unusual wedge pressure tracing.

Authors:  O S Takkunen; E A Kalso
Journal:  Can J Anaesth       Date:  1987-03       Impact factor: 5.063

2.  Treatment of pulmonary artery haemorrhage with a single lumen tracheal tube.

Authors:  D Mangar
Journal:  Can J Anaesth       Date:  1994-09       Impact factor: 5.063

3.  Complications of the Swan-Ganz catheter.

Authors:  H B Slung; K S Scher
Journal:  World J Surg       Date:  1984-02       Impact factor: 3.352

4.  [Pulmonary artery perforations as typical complication in the use of Swan-Ganz catheters].

Authors:  K Lieske; K Püschel; M Doehn
Journal:  Z Rechtsmed       Date:  1985

5.  Balloon occlusion femoral angiography prior to in-situ saphenous vein bypass.

Authors:  J F Cardella; T P Smith; M D Darcy; D W Hunter; W Castaneda-Zuniga; K Amplatz
Journal:  Cardiovasc Intervent Radiol       Date:  1987       Impact factor: 2.740

Review 6.  Invasive monitoring in patients with heart failure.

Authors:  Saima Husain; Salpy V Pamboukian; Josè A Tallaj; David C McGiffin; Robert C Bourge
Journal:  Curr Cardiol Rep       Date:  2009-05       Impact factor: 2.931

Review 7.  Hemodynamic monitoring: a technology assessment. Technology Subcommittee of the Working Group on Critical Care, Ontario Ministry of Health.

Authors: 
Journal:  CMAJ       Date:  1991-07-15       Impact factor: 8.262

8.  Catheter-induced pulmonary artery haemorrhage resulting from a pneumothorax.

Authors:  D Mangar; G R Connell; J L Lessin; J Räsänen
Journal:  Can J Anaesth       Date:  1993-11       Impact factor: 5.063

Review 9.  Perforation of the pulmonary artery with Swan-Ganz catheters: diagnosis and surgical management.

Authors:  T F Kelly; G C Morris; E S Crawford; R Espada; J F Howell
Journal:  Ann Surg       Date:  1981-06       Impact factor: 12.969

10.  Pulmonary artery catheter infections. A prospective study.

Authors:  M L Myers; T W Austin; W J Sibbald
Journal:  Ann Surg       Date:  1985-02       Impact factor: 12.969

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.