Literature DB >> 4253459

The electrocardiogram, vectorcardiogram and spatiocardiogram in the rabbit.

M Szabuniewicz, D Hightower, J R Kyzar.   

Abstract

Standard, augmented limb leads and three orthogonal leads (I, aVF and V(10)) taken simultaneously were recorded from 25 rabbits. Records were analyzed for rate, rhythm, interval duration and component amplitudes. The wave forms of QRS complexes were analyzed in all leads. P, QRS, and T vectors were calculated for the mean frontal (dorsal), sagittal, and transverse planes. Study of orthogonal leads in sternal recumbency indicated that ventricular activation is spatially oriented sinistrad or dextrad, ventrad and caudad.

Entities:  

Mesh:

Year:  1971        PMID: 4253459      PMCID: PMC1319558     

Source DB:  PubMed          Journal:  Can J Comp Med        ISSN: 0008-4050


  11 in total

1.  HIGH-FIDELITY ELECTROCARDIOGRAMS OF NORMAL RABBITS.

Authors:  C V NELSON; W C WAGGONER; P R GASTONGUAY
Journal:  Am J Physiol       Date:  1964-11

2.  [Standard and thoracic lead electrocardiography in normal rabbits and methods for its registration].

Authors:  A O SAITANOV
Journal:  Biull Eksp Biol Med       Date:  1960-06

3.  [Observations on the electrocardiogram of rabbits. I. Normal limb electrocardiogram of rabbits].

Authors:  L SLAPAK; P HERMANEK
Journal:  Z Kreislaufforsch       Date:  1957-02

4.  [Observations on the electrocardiogram of rabbits. II. Normal precordial electrocardiogram of rabbits].

Authors:  L SLAPAK; P HERMANEK
Journal:  Z Kreislaufforsch       Date:  1957-02

5.  Further studies of the electrocardiographic spatial magnitude curve (in the rabbit).

Authors:  B M SAYERS; F G SILBERBERG
Journal:  Am Heart J       Date:  1957-04       Impact factor: 4.749

6.  An accurate, clinically practical system for spatial vectorcardiography.

Authors:  E FRANK
Journal:  Circulation       Date:  1956-05       Impact factor: 29.690

7.  The effect of intravenous trypsin administration on the electrocardiogram of the rabbit.

Authors:  J S LIEBERMAN; A TAYLOR; I S WRIGHT
Journal:  Circulation       Date:  1954-09       Impact factor: 29.690

8.  [Electrocardiography in the rabbit].

Authors:  T PETELENZ; S KOSMIDER
Journal:  Acta Physiol Pol       Date:  1961 Jul-Aug

9.  Categorization of common domestic mammals based upon their ventricular activation process.

Authors:  R L Hamlin; C R Smith
Journal:  Ann N Y Acad Sci       Date:  1965-09-08       Impact factor: 5.691

10.  Clinical use of the electrocardiogram in animals. 3. Vectorial analysis.

Authors:  J D McCrady; D R Clark; M Szabuniewicz
Journal:  Vet Med Small Anim Clin       Date:  1966-10
View more
  4 in total

1.  Dipole moment of in vivo and isolated perfused rabbit hearts.

Authors:  C V Nelson; B C Hodgkin
Journal:  Ann Biomed Eng       Date:  1989       Impact factor: 3.934

2.  Thoracic cage plasticity in prepubertal New Zealand white rabbits submitted to T1-T12 dorsal arthrodesis: computed tomography evaluation, echocardiographic assessment and cardio-pulmonary measurements.

Authors:  Federico Canavese; Alain Dimeglio; Marco Stebel; Marco Galeotti; Bartolomeo Canavese; Fabio Cavalli
Journal:  Eur Spine J       Date:  2013-01-10       Impact factor: 3.134

3.  Preliminary reference values for electrocardiography, echocardiography and myocardial morphometry in the European brown hare (Lepus europaeus).

Authors:  Agnieszka Noszczyk-Nowak; Józef Nicpoń; Marcin Nowak; Piotr Slawuta
Journal:  Acta Vet Scand       Date:  2009-01-30       Impact factor: 1.695

4.  Effect of thoracic arthrodesis in prepubertal New Zealand white rabbits on cardio-pulmonary function.

Authors:  Federico Canavese; Alain Dimeglio; Davide Barbetta; Bruno Pereira; Sergio Fabbro; Federica Bassini; Bartolomeo Canavese
Journal:  Indian J Orthop       Date:  2014-03       Impact factor: 1.251

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.