Analysis of six hundred and twenty-two intertrochanteric hip fractures.

R F Kyle, R B Gustilo, R F Premer.   

Abstract

Of 622 intertrochanteric fractures, 57% were stable (Types I and II). Twenty-eight per cent were Type III, and 15% were Type IV (the unstable types). The 150-degree telescoping Massie nail proved superior to the fixed 135-degree Jewett nail (particularly for unstable fractures) because it allowed a controlled impaction of the fracture fragments to a stable position. In about one-third of the fractures, some medial displacement occurred. With anatomical reduction and the use of the Massie or ASIF nails, we achieved a decrease in the morbidity and mortality and 96% satisfactory results. Our prospective study was compared with a retrospective study in which other devices were used. Early ambulation and weight-bearing also was a major contributing factor to the improved results in the prospective study. Intertrochanteric hip fractures that are unstable can be fixed with a collapsible nail, and that treatment appears to give as good or better results than the displacement method of Dimon and Hughston or Sarmiento.

Entities:  

Mesh:

Year:  1979        PMID: 422605

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  67 in total

1.  Analysis of the micro-migration of sliding hip screws by using point-based registration.

Authors:  Patrik Raudaschl; Karl Fritscher; Tobias Roth; Christian Kammerlander; Rainer Schubert
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-06-23       Impact factor: 2.924

2.  Biomechanical analysis of the dynamic hip screw in the treatment of intertrochanteric fractures.

Authors:  C C Wu; C H Shih
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

3.  Fixation of basicervical and related fractures.

Authors:  Elsayed Ibraheem Elsayed Massoud
Journal:  Int Orthop       Date:  2009-05-28       Impact factor: 3.075

4.  A meta-analysis of the Gamma nail and dynamic hip screw in treating peritrochanteric fractures.

Authors:  Ming Liu; Zhiming Yang; Fuxing Pei; Fuguo Huang; Shiqiang Chen; Zhou Xiang
Journal:  Int Orthop       Date:  2009-04-29       Impact factor: 3.075

5.  Minimally invasive dynamic hip screw for fixation of hip fractures.

Authors:  Michael Ho; Giorgio Garau; Gayle Walley; Francesco Oliva; Alfredo Schiavone Panni; Umile Giuseppe Longo; Nicola Maffulli
Journal:  Int Orthop       Date:  2008-05-14       Impact factor: 3.075

6.  An abduction-traction frame for the treatment of intertrochanteric fracture of femur.

Authors:  S H Yang; J Y Du; T B Zhu
Journal:  J Tongji Med Univ       Date:  1995

7.  A comparison of two fixation methods for femoral trochanteric fractures: a new generation intramedullary system vs sliding hip screw.

Authors:  Christian Carulli; Federico Piacentini; Tommaso Paoli; Roberto Civinini; Massimo Innocenti
Journal:  Clin Cases Miner Bone Metab       Date:  2017-05-30

8.  Primary hemiarthroplasty for unstable osteoporotic intertrochanteric fractures in the elderly: A retrospective case series.

Authors:  Kh Sancheti; Pk Sancheti; Ak Shyam; S Patil; Q Dhariwal; R Joshi
Journal:  Indian J Orthop       Date:  2010-10       Impact factor: 1.251

9.  Unstable trochanteric fractures: the role of lateral wall reconstruction.

Authors:  R K Gupta; Kapil Sangwan; Pradeep Kamboj; Sarabjeet S Punia; Pankaj Walecha
Journal:  Int Orthop       Date:  2009-03-14       Impact factor: 3.075

10.  Role of gamma nail in management of pertrochanteric fractures of femur.

Authors:  Vipin Sharma; Sushrut Babhulkar; Sudhir Babhulkar
Journal:  Indian J Orthop       Date:  2008-04       Impact factor: 1.251